12
6.1.6 Regeneration frequency setup (models with softener)
•
Default value:
H00
; modify the parameter to suit the mains water hardness.
•
Generally
H03
will be satisfactory for most users.
•
At first use, the salt tank has to be filled. It is subsequently sufficient simply to fill up with regenerating salt
when necessary.
Hardness
(°dH german
degrees)
Hardness
(°dF French
degrees)
Setting level
Regeneration off Regeneration off
H00
8,5 15 H01
11 20 H02
Modify the value
of the parameter
by pressing .
17 30 H03
22,5 40 H04
28 50 H05
Regeneration cycle duration:
12 minutes
33,5
60
H06
With values over 60°dF an external water treatment device must be used and the regeneration frequency
must be
set on H00
.
6.1.7 tStP (minimum rinsing temperature) function
Modify the parameter (ON/OFF) by pressing .
Set at “on” for minimum rinsing temperature as set.
Set as “off” to accept minimum rinsing temperature a few degrees lower than the setting if hot intake water is not
used.
6.1.8 Rinse aid pump
To reset, press
for 3 seconds.
Display (also reset when needed)
6.1.9 Detergent pump
To reset, press
for 3 seconds.
Display (also reset when needed)
6.1.10 Energy consumption – Display and reset
To reset, press
for 3 seconds.