3
2 Technical
data
TECHNICAL DATA
Supply voltage
V
400V 3N ~
- convertible to single-phase version
V
230V -1N ~
Frequency
Hz
50
Max. power absorption at 400V 3N ~
kW
5,7
Max. power absorption at 230V 1N ~
kW
2,4
Boiler heating element power at 400V 3N ~
kW
5,0
Boiler heating element power at 230V 1N ~
kW
1,7
Tank heating element power
kW
0,8
Water intake pressure
kPa (bar)
100-600 (1 ÷ 6)
Water intake temperature
°C
15°C – 60°C
Water hardness (models with softener)
°f
15°f-60°f
Rinse cycle water consumption
I
3.5
Boiler capacity
I
7 + 1
Tank capacity
I
11
Standard cycle duration with intake water at 50°C
s
90/150/240/variable
Noise level
dB(A)
Degree of protection
IPX
4
Net weight
kg
Power supply cable type
◄
HAR
►
H07RN-F
Fuse
A
4
R
LOWER BACK PANEL
C
FILLER HOSE
Q
EARTH TERMINAL
E
ELECTRICITY SUPPLY CABLE
P
PERISTALTIC HOSES
S
DRAIN HOSE
T
EXTERNAL DISPENSER POWER
SUPPLY CABLE ENTRY POINT
M
TERMINAL BOARD
Summary of Contents for CW501D