Instructions for the installer
71
13.INSTALLING THE APPLIANCE
The appliance must be installed by a qualified technician and according to the
regulations in force. Depending on the type of installation, it belongs to class 1
(Fig.
A
) or to class 2, subclass 1 (Fig.
B-C
).
This appliance may be installed next to walls, one of which must be higher than
the appliance, at a minimum distance of 50 mm from the side of the appliance,
as shown in drawings
A
and
B
relative to the installation classes. Any wall
cupboards or ventilation hoods must be at a distance of at least
750 mm
above
the work surface.
13.1 Electrical connection
The identification plate bearing the technical data, serial number and brand
name is visibly positioned on the appliance. Make sure the voltage and the
cross-section of the power supply line match the specifications indicated on the
identification plate positioned in the storage compartment.
Do not remove this plate for any reason.
The appliance must be connected to earth in compliance with electrical system
safety regulations.
A
B
C
50mm
750mm
50mm
50mm
750mm
50mm