Installation
41
EN
The appliance can work in the following
modes:
•
220-240 V 1N
~
use a
3 x 4 mm²
three-core
cable.
•
380-415 V 2N
~
use a
4 x 4 mm²
four-core
cable.
•
380-415 V 3N
~
use a
5 x 1.5 mm²
five-core
cable.
Fixed connection
Fit the power line with an all-pole
disconnection switch, with a clearance
between its contacts that allows the
complete disconnection as per the
overvoltage category III, in compliance
with the installation regulations.
5.5 For the installer
• The plug must remain accessible after the
installation is complete. Do not kink or
trap the mains connection cable.
• The appliance must be fitted according
to the installation diagrams.
• Do not attempt to turn or stress the
threaded elbow on the manifold. You risk
damage to this part of the appliance
which may void the manufacturer’s
warranty.
• Before leaving check all connections for
gas leaks with soap and water. DO
NOT use a naked flame for detecting
leaks.
• Ignite all burners individually and
concurrently to ensure correct operation
of the gas valves, burner and ignition.
• Turn the gas knobs to the low position
and observe stability of the flame for
each burner individually and all together.
• In case the appliance fails to operate
correctly after all checks have been
carried out, refer to the Authorised
Assistance Centre in your area.
• When satisfied with the appliance,
please instruct the user on the correct
method of operation.
The values indicated above refer
to the cross-section of the internal
conductor.
The aforementioned power cables
are sized taking into account the
coincidence factor (in compliance
with standard EN 60335-2-6).