How to Order Manifold
Rubber Seal/3 Port/Pilot Poppet Type Manifold
Common Exhaust
Type
41
/
Individual Exhaust
Type
42
Series
VP300/500/700
VV3P 3
1
41
04
02
Series
3
5
7
VP300
VP500
VP700
Pilot type
—
R
Internal pilot
External pilot
Thread type
—
F
N
T
Rc
G
NPT
NPTF
Stations
02
20
2 stations
20 stations
Port size
02
03
04
Symbol
Port size
Applicable series
1/4
3/8
1/2
VP300
VP500
VP700
···
···
VV3P 3
3
42
04
02
Series
3
5
7
VP300
VP500
VP700
Thread type
—
F
N
T
Rc
G
NPT
NPTF
Stations
02
20
2 stations
20 stations
Port size
02
03
04
Symbol
Port size
Applicable series
1/4
3/8
1/2
VP300
VP500
VP700
···
···
Type 41/Common exhaust
Type 42/Individual exhaust
Note) When the external
pilot type manifold is
selected, external
pilot type valves are
mounted.
Pilot type
—
R
Internal pilot
External pilot
Note) When the external
pilot type manifold is
selected, external
pilot type valves are
mounted.
How to Order Valve
(With a gasket and two mounting bolts)
VP 3 4 4
5 G
1 A
Series
3
5
7
VP300
VP500
VP700
Type of actuation
A
B
N.C. (Normally closed)
N.O. (Normally open)
5
6
24 VDC
12 VDC
Pilot type
—
R
Internal pilot
External pilot
Light/surge voltage suppressor
DC AC
—
S
Z
R
U
Without light/surge voltage suppressor
With surge voltage suppressor
With light/surge voltage suppressor
With surge voltage suppressor (Non-polar)
With light/surge voltage suppressor (Non-polar)
Manual override
Pressure specification
—
K
Standard (0.7 MPa)
High-pressure type (1.0 MPa)
Electrical entry
Coil specification
—
T
Standard
With power saving circuit (DC only)
Note 1) Be sure to select the power saving circuit
type when it is continuously energized for
a long time. (Refer to back page 7 for
details.)
Note 2) T type is only available for DC mode.
When T is selected, only Z type of
light/surge voltage suppressor is available.
(Note that when the electrical entry of DIN
terminal type without connector is
selected, only DOS and YOS are
available.)
Note 1) There is no S option for AC mode, since a rectifier prevents
surge voltage generation.
Note 2) In the DIN terminal type, since a light is installed in the con-
nector, DOZ, DOU, YOZ, YOU are not available.
Rated voltage
DC
1
2
3
4
7
100 VAC
200 VAC
110 VAC [115 VAC]
220 VAC [230 VAC]
240 VAC
AC (50/60 Hz)
When using the surge voltage suppressor type,
residual voltage will remain. Refer to back page 7
for details.
Caution
Note 1) LN and MN types are with 2 sockets.
Note 2) Refer to back page 4 when different length of lead wire for L/M-type plug connector is
required.
Note 3) Refer to back page 5 for details on the DIN (EN175301-803) terminal.
Note 4) The AC mode of G, H, L and M types are not CE compliant.
Made to Order
—
X500
—
Pilot exhaust port with piping thread (M3)
specification (Refer to page 24).
Grommet
Conduit
terminal
L-type plug
connector
M-type plug
connector
DIN
terminal
DIN
(EN175301-803)
terminal
G
: Lead wire
length 300 mm
H
: Lead wire
length 600 mm
L
: With lead wire
(length 300 mm)
LN
:
Without lead wire
LO
:
Without connector
M
: With lead wire
(length 300 mm)
D
: With connector
Y
: With connector
T
: Conduit
terminal
DO
:
Without connector
YO
:
Without connector
MN
:
Without lead wire
MO
:
Without connector
G
: Lead wire
length 300 mm
H
: Lead wire
length 600 mm
DC
Without light/
surge voltage
suppressor
—:
Non-locking
push type
D
:
Push-turn locking
slotted type
E
:
Push-turn locking
lever type
[IP65 compatible] [IP65 compatible] [IP65 compatible]
Note) Only DIN and conduit
terminal types are
available for AC mode.
Refer to the electrical
entry for details.
Note 1)
Note) Only DIN and conduit terminal
types can be set for AC mode. Refer
to the electrical entry for details.
Series
VP300/500/700
Pilot Poppet Type
Common Exhaust
Type 41
/Individual Exhaust
Type 42
15