V211
Pilot valve assembly
DIN connector
(Refer to back page 5.)
V212
Pilot valve assembly
How to Order Pilot Valve Assembly
When only the pilot valve assembly is replaced, it is not possible to change from V211 (Grommet or L/M-type) to V212 (DIN or Conduit
type), or vice versa.
Caution
For V212 (DIN or Conduit type), the coil specification and voltage (including light/surge voltage suppressor) cannot be changed by
changing the pilot valve assembly.
Caution
Tightening torque of the pilot valve assembly mounting screw
M2.5: 0.32 N·m
Caution
VP
1
5 G Z
5
6
24 VDC
12 VDC
Light/surge voltage suppressor
DC AC
—
S
Z
R
U
Without light/surge voltage suppressor
With surge voltage suppressor
With light/surge voltage suppressor
With surge voltage suppressor (Non-polar)
With light/surge voltage suppressor (Non-polar)
Pressure specification
—
K
Standard (0.7 MPa)
High-pressure type (1.0 MPa)
G
H
L
LN
LO
M
MN
MO
Grommet (Lead wire length 300 mm)
Grommet (Lead wire length 600 mm)
With lead wire
Without lead wire
Without connector
With lead wire
Without lead wire
Without connector
Electrical entry
Coil specification
—
T
Standard
With power saving circuit (DC only)
Note) T type is only available for DC mode.
Note) There is no S option for AC mode, since a rectifier prevents
surge voltage generation. When T is selected, only Z type of
light/surge voltage suppressor is available.
Rated voltage
DC
1
2
3
4
7
100 VAC
200 VAC
110 VAC [115 VAC]
220 VAC [230 VAC]
240 VAC
AC (50/60 Hz)
When using the surge voltage suppressor type,
residual voltage will remain. Refer to back page 7
for details.
Caution
L-type plug
connector
M-type plug
connector
DIN or Conduit type
5 G Z
5
2
V
1 1
2
V
1 2
Note) Select from the below in accordance with the valve used.
Note 1) LN and MN types are with 2 sockets.
Note 2) Refer to back page 4 when different
length of lead wire for L/M-type plug
connector is required.
Valve model:
Grommet or L/M-type
Note)
Series
VP300/500/700
Approx. 300
(Lead wire length)
97.3
66.7
38
X
Max. 10
102.9
106.7
97.7
Applicable cable O.D.
ø4.5 to ø7
Pg9
X
Approx. 300
(Lead wire length)
77.7
94
88.9
X
102.4
Approx. 300
(Lead wire length)
66.7
44
X
39
34
19.5
66.7
24
59
17
.5
12
1/8, 1/4
1(P) port
M5 x 0.8
External pilot port
PE port
Note)
(ø3.8)
X
19.5
12
1/8, 1/4
2(A) port
1.3
96.1
35
Approx. 300
(Lead wire length)
43
57.6
6.7
11.2
30
2 x ø4.2
(For mounting)
Manual override
2A
NO
1P
NC
NC
18.5
12
1/8, 1/4
3(R) port
3R
43.7
18.5
(Indicator light)
+
–
110.9 [100.9]
100.9 [90.9]
Max. 10
105.3
Pg9
(Indicator light)
Applicable cable O.D.
ø4.5 to ø7
X
Note) Refer to page 24 when piping to PE port is
required.
Series VP300/Base Mounted/Dimensions
Grommet (G)
Grommet (G)
DC without light/surge voltage suppressor
DIN terminal (D, Y)
M-type
plug connector (M)
L-type
plug connector (L)
Conduit terminal (T)
Unless otherwise indicated, dimensions are the same as Grommet (G).
[ ] valves: Without indicator light
Series
VP300/500/700
Pilot Poppet Type
Base Mounted/Single Unit
11