background image

Doc. No.VK300

**

-OMH0002-C 

 

 

 

 

 

 

 

 

 

PRODUCT NAME

 

 

3/5 Port Solenoid Valve

 

 

MODEL/ Series

 

 

VK300/3000 Series

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for VK300 series

Page 1: ...Doc No VK300 OMH0002 C PRODUCT NAME 3 5 Port Solenoid Valve MODEL Series VK300 3000 Series...

Page 2: ...ety Instructions 2 3 Design Selection 4 5 Mounting 5 Piping 5 6 Wiring 6 Lubrication 6 Air Supply 6 Operating Environment 7 Maintenance 7 Specific Product Precautions 8 12 Trouble shooting 13 14 1 VK3...

Page 3: ...when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembly operat...

Page 4: ...oduct 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this 1 year...

Page 5: ...y adversely affect the performance of the valve and any nearby peripheral equipment Therefore when the total energizing time per day is expected to be longer than the total de energizing time per day...

Page 6: ...ntenance and inspection 3 Tighten threads with the proper tightening torque When installing the products follow the listed torque specifications 4 If air leakage increases or equipment does not operat...

Page 7: ...age Compressed air containing a large amount of drainage can cause the malfunction of pneumatic equipment An air dryer or water separator should be installed upstream from filters 3 Drain flushing If...

Page 8: ...ection according to the procedures indicated in the operation manual this document If handled improperly human injury and or malfunction or damage of machinery and equipment may occur 2 Removal of equ...

Page 9: ...ht with lead wire Precautions Plug a connector in or out vertically never at an angle Applicable cable O D 3 5 to 7 Reference 0 5 mm2 2 core and 3 core wires equivalent to JIS C 3306 Connector part no...

Page 10: ...rates But even in low cycle rates if energizing the valve more than once a day please consult with SMC 2 Energizing solenoid should be done at least once in 30 days 3 As a rectifier is mounted to the...

Page 11: ...1A VK300 41 2A Type 20 VV3K3 20 Body ported A port top ported Type 40 VV3K3 40 Base mounted A port bottom ported Type 42 VV3K3 42 Base mounted A port side ported Type S42 VV3K3 S42 Solenoids on the s...

Page 12: ...A Combinations of Solenoid Valve Manifold Gasket and Manifold Base Mixed Mounting of VK300 and Manifold Base of VK3000 Series Combination of Blanking Plate Assembly and Manifold Base Blanking plate as...

Page 13: ...B port bottom ported Type 41 VV5K3 41 Base mounted A B port side ported Type 42 VV5K3 42 Base mounted A B port side ported Type 21 VV5K3 21 Body ported A B port top ported Type S41 VV5K3 S41 Type S42...

Page 14: ...ge Leakage at actuator cylinder etc side Leakage Foreign matter caught in the spool valve Foreign matter caught in core of solenoid valve Worn core Low line voltage Inferior tightening of installation...

Page 15: ...Prohibited way of using the valve which is written at Precautions section in this operation manual 3 Lubrication has been stopped intermediately or lubrication was suspended temporary 4 Water splashe...

Page 16: ...rinting TZ 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any oblig...