background image

 

- - 7 - -

 

- 7 - 

 

VG300

∗∗−

OMH0002-B

 

 

Operating Environment

 

 

 

1.  Do  not  use  in  an  atmosphere  having  corrosive 

gases, chemicals, sea water, water, water steam, 

or  where  there  is  direct  contact  with  any  of 

these.   

2.  Do  not  use  in  an  environment  where  flammable 

gas  or  explosive  gas  exists.  Usage  may  cause  a 

fire  or  explosion.  The  products  do  not  have  an 

explosion proof construction. 

3. Do not use in a place subject to heavy  vibration 

and/or shock.   

4.  The  valve  should  not  be  exposed  to  prolonged 

sunlight. Use a protective cover. 

5. Remove any sources of excessive heat. 

6.  If  it  is  used  in  an  environment  where  there  is 

possible  contact  with  oil,  weld  spatter,  etc., 

exercise preventive measures. 

7. When the solenoid valve is mounted in a control 

panel or its energized for a long time, make sure 

ambient  temperatures  is  within  the  specification 

of the valve. 

 

Maintenance

 

 

 

1.  Perform  maintenance  inspection  according  to 

the  procedures  indicated  in  the  operation 

manual. 

If  handled  Improperly,  malfunction  and  damage  of 

machinery or equipment may occur. 

2.   Removal  of  equipment,  and  supply / exhaust  of 

compressed air 

When  components  are  removed,  first  confirm  that 

measures are in place to prevent workpieces from dropping,     

run-away equipment, etc. Then, cut off the supply pressure 

and electric power, and exhaust all compressed air from the 

system using the residual pressure release function. 

When  the  equipment  is  operated  after  remounting  or 

replacement,  first  confirm  that  measures  are  in  place  to 

prevent  lurching  of  actuators,  etc.  Then,  confirm  that  the 

equipment is operating normally. 

3. Low frequency operation 

Valves should  be  operated  at  least  once  every  30  days to 

prevent malfunction. (Use caution regarding the air supply.) 

4. Manual override 

When  the  manual  override  is  operated,  equipment  will  be 

actuated. 

Operate after safety is confirmed. 

 
 

1. Drain flushing 

Remove drainage from the air filters regularly. 

2. Lubrication 

Once lubrication has been started, it must be continued. 

Use  class  1  turbine  oil  (with  no  additive),  ISO  VG32 

because  if  other  lubricant  oil  is  used,  it  may  cause 

malfunction.  Please  contact  SMC  for  suggested  class  2 

turbine oil (with additive), ISO VG32. 

 
 

VG342 Series 

3 Port Solenoid Valve / Precautions 4

    

 

Be sure to read before handling.

 

 

Warning 

Caution 

 

 

Warning 

Summary of Contents for VG342 Series

Page 1: ...Doc No VG300 OMH0002 B 3 Port Solenoid Valve PRODUCT NAME VG342 Series MODEL Series...

Page 2: ...Safety Instructions 2 3 Precautions on Design 4 5 Selection 4 5 Mounting 5 Piping 5 6 Wiring 6 Lubrication 6 Air Supply 6 Operating Environment 7 Maintenance 7 Specific Product Precautions 8 9 Trouble...

Page 3: ...of equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectl...

Page 4: ...lacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product 3 Prior to u...

Page 5: ...n pad or air leakage causing the workpiece to drop 7 Regarding a vacuum switch valve and a va cuum release valve If a non vacuum valve is installed in the middle of piping system having a vacuum the v...

Page 6: ...lished specifications is supplied to the external pilot type valve s port 6 Mounting orientation Mounting orientation is free Mounting 1 Operation manual Install the products and operate them only aft...

Page 7: ...f pneumatic equipment An air dryer or water separator should be installed upstream from filters 3 Drain flushing If condensation in the drain bowl is not emptied on a regular basis the bowl will overf...

Page 8: ...emoval of equipment and supply exhaust of compressed air When components are removed first confirm that measures are in place to prevent workpieces from dropping run away equipment etc Then cut off th...

Page 9: ...of internal pilot confirm that a plug is inserted to X port If not insert a R1 8 plug Note 2 In the case of external pilot supply air pressure from X port Confirm the safety sufficiently and conduct...

Page 10: ...then insert into the housing 2 2 From the terminal block 3 loosen the screw 11 then pass the lead wire 10 through then again tighten the screw 11 Note 1 Tighten within the tightening torque of 0 5 N...

Page 11: ...al on actuator cylinder etc side In case of N O EXH port is 1 P port Intrusion of foreign matter Coil splashed by water Trouble phenomenon Broken coil wire Foreign matter caughtin armature Changeover...

Page 12: ...actuators Isolate the valve and re tighten the bolts 13 14 Place the changeover plates to the proper position If no improvement is achieced in spite of the above countermeasure inside of the valve ma...

Page 13: ...rinting HT 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any oblig...

Reviews: