- - 9 - -
- 9 -
VG300
∗∗
-OMH0002-B
If energizing the valve for a long time, use “VG342
□
-
□□□
-
□□□
-E” (Pilot valve assembly: “VO307E-
□□□
-X84”).
1. This model is for continuous duty, not for high cycle rates.
But even in low cycle rates, if energizing the valve more
than once a day, please consult with SMC.
2. Make sure to cycle valve at least once every 30 days.
How to Use DIN Terminal
1. Disassembly
1) After loosening the screw (1), then if the housing (2) is
pulled in the direction of the screw, the connector will
be removed from the body of equipment (solenoid,
etc.).
2) Pull the screw (1) out of the housing (2).
3) On the bottom part of the terminal block (3), there’s a
cut-off part (9). If a small flat head screwdriver is
inserted between the opening in the bottom, terminal
block (3) will be removed from the housing (2). (Refer
to Figure-1.)
4) Remove the cable gland (4) and plain washer (5) and
rubber seal (6).
2. Wiring
1) Pass them through the cable (7) in the order of cable
ground (4), washer (5), rubber seal (6), and then insert
into the housing (2).
2) From the terminal block (3), loosen the screw (11), then
pass the lead wire (10) through, then again tighten the
screw (11).
Note 1) Tighten within the tightening torque of 0.5 N
・
m
+/-15%.
Note 2) Cable (7) external:
φ
6 to
φ
8 mm
Figure-1
3. Assembly
1) Passing through the cable (7), the cable gland (4),
plain washer (5), and rubber seal (6), housing (2) in
this order, and then connect with the terminal block (3).
After that, set the terminal block (3) on the housing (2).
(Push it down until you hear the click sound.)
2) Putting rubber seal (6), plain washer (5), in this order
into the cable introducing slit on the housing (2), then
further tighten the cable gland (4) securely.
3) Insert the gasket (8) or between the bottom part of
terminal block (3) and a plug attached to equipment,
and then screw (1) in from the top of the housing (2) to
tighten it.
Note 1) Tighten within the tightening torque of 0.5 N
・
m
+/-20%.
Note 2) Connector orientation can be changed by 180
degrees depending on how to assemble the
housing (2) and the terminal block (3).
Continuous Duty
VG342 Series
3 Port Solenoid Valve /
Specific Product 2
Be sure to read before handling.
Caution
(4)
(5)
(6)
(11) (9) (10)
(7)
(8)
(1)
(2)
(3)