background image

1.17-1

 5 Port Pilot Solenoid Valve

 

Metal Seal

Series

VFS

Models and Variations

Series

Port Size

 

Effective area

(mm

2

) (N

l

/min)

Configuration Voltage

Electrical entry

Option

(Indicator light and surge suppressor)

Manual 

override

Body ported 

VFS1000

VFS2000

VFS3000

2 position single

2 position double

3 position closed centre

 3 position exhaust centre

3 position pressure centre

Standard

100V AC50/60Hz
200V AC50/60Hz
24V DC

Option

110 to 120V AC50/60Hz

220V AC50/60Hz
240V AC50/60Hz
12V DC
100V DC

1 8

DIN connector
(D)(Y)

Conduit terminal
(F)

Plug-in

Non plug-in

DIN connector 
(D)(Y)

Conduit terminal (F)

Plug-in

Non plug-in

    With indicator light and 
     surge voltage suppressor

•Din connector (DZ)(YZ)

Locking style (Lever) is not available for direct mount series VFS2000, 3000.

Non plug-in

      Din connector (DZ)(YZ)

    With indicator light and 
    surge voltage suppressor

•Plug-in
   Conduit terminal (FZ)
•Non plug-in
      Din connector (DZ)(YZ)

Non-locking 

push style

(Flush)

Non-locking 

push style

(Extended)

Locking style

(Slotted)

Locking style

(Lever)

Base mounted

2 position single

2 position double

2 position single

2 position double

3 position closed centre

3 position exhaust centre

3 position pressure centre

3 position double check

Standard

100V AC50/60Hz
200V AC50/60Hz
24V DC

Option

110 to 120V AC50/60Hz

220V AC50/60Hz
240V AC50/60Hz
12V DC
100V DC

DIN connector 
(D)(Y)

Non-locking 

push style

(Flush)

Non-locking 

push style

(Extended)

Locking style

(Slotted)

Locking style

(Lever)

Non-locking 

push style

(Flush)

VFS2000

Plug-in
Non plug-in

VFS3000

Plug-in
Non plug-in

VFS4000

Plug-in
Non plug-in

VFS5000

Plug-in
Non plug-in

VFS6000

Plug-in
Non plug-in

    : 9.0 (491)

1 8

    : 16.2 (883)

   : 18 (981)

1 4   

   : 32.4 (1777)

   : 36.0 (1963)

1 4
3 8

   : 12.6 (687)

   : 15 (815)

1 8
1 4

   : 32.4 (1777)

   : 36.0 (1963)

1 4
3 8

   : 59.4 (3239)

   : 64.8 (3533)

3 8
1 2

   : 162 (8833)

 1: 180 (9815)

3 4

   : 78.7 (4319)

   : 97.2 (5300)

3 8
1 2

   : 102.6 (5595)

3 4

Summary of Contents for VFS Series

Page 1: ...ht and surge voltage suppressor Plug in Conduit terminal FZ Non plug in Din connector DZ YZ Non locking push style Flush Non locking push style Extended Locking style Slotted Locking style Lever Base...

Page 2: ...ted VFS1000 VFS2000 VFS3000 Base Mounted Plug in VFS2000 VFS3000 VFS4000 VFS5000 Base Mounted Non Plug in VFS2000 VFS3000 VFS4000 VFS5000 Bar base Series VFS1000 2000 Plug in Non plug in 1 17 2 Manifo...

Page 3: ...Air release valve spacer Double check spacer SUP EXH block disk Manifold Options Manifold Optional Parts With control unit With exhaust cleaner 1 1 1 1 Serial interface unit Individual SUP spacer Indi...

Page 4: ...interior wiring is shown below Please connect with corresponding power side Changing Direction of DIN Connector Cable Entry AC and 100V DC 24V DC or less 24V DC or less Wiring In the case of DIN conne...

Page 5: ...g in style Then when changing the rated voltage with light surge voltage suppressor change of light surge volt age suppressor substrate is also needed So order together with pilot valve assembly Light...

Page 6: ...4 to 25 M5 28 to 50 Interface Regulator Specifications Model Applicable solenoid valve series Regulation Proof pressure Max operating pressure ARBF2000 ARBF3050 ARBF4050 ARBF5050 VFS2000 VFS3000 VFS40...

Page 7: ...ug q into the manifold base push the lever area of insert plug with thumb and plug it in its place in the receptacle housing r horizontally After plugging pull lead wire out a little bit to ensure tha...

Page 8: ...lug Assembly Option Wire Color Table GVVZS3000 21A 1S GVVZS3000 21A 2S Assembly part No Cable length 1m 3m GVVZS3000 21A 3S 5m GVVZS3000 21A 4S 8m GVVZS3000 21A 5S 20m Components Plug MIL standard D t...

Page 9: ...bient and fluid temperature 1 5MPa Proof pressure Lubrication Pilot valve manual override Shock vibration resistance Protection structure Rated voltage Allowance voltage Class B or equivalent 5 Coil i...

Page 10: ...ve class class I Mark VFS1 1 20 01 Configuration 1 2 position single 2 2 position double 3 3 position closed centre 4 3 position exhaust centre 5 3 position pressure centre Electrical entry D DIN conn...

Page 11: ...3 position closed centre exhaust centre pressure centre Replacement Parts Closed centre Exhaust centre Pressure centre No y t Description Material Stainless steel Part No Return spring Pilot valve ass...

Page 12: ...1 17 12 DIN Connector Grommet VFS1120 G Grommet terminal VFS1120 E EZ DIN connector VFS1120 D DZ With bracket F AXT626 10A Conduit terminal VFS1120 T TZ VFS1000 2 Position Single...

Page 13: ...FS1520 G Grommet terminal VFS1220 E EZ VFS1320 E EZ VFS1420 E EZ VFS1520 E EZ DIN connector VFS1220 D DZ VFS1320 D DZ VFS1420 D DZ VFS1520 D DZ Conduit terminal VFS1220 T TZ VFS1320 T TZ VFS1420 T TZ...