3-1
C
HAPTER
3
I
NSTALLING
THE
S
WITCH
Selecting a Site
TigerSwitch 10/100 units can be mounted in a standard 13-inch
equipment rack or on a flat surface. Be sure to follow the guidelines below
when choosing a location.
◆
The site should:
•
be at the center of all the devices you want to link and near a
power outlet.
•
be able to maintain its temperature within 0° to 50° C (32 to
122 °F) and its humidity within 10% to 90%, non-condensing
•
provide adequate space (approximately two inches) on all sides for
proper air flow
•
be accessible for installing, cabling and maintaining the devices
•
allow the status LEDs to be clearly visible
◆
Make sure twisted-pair cable is always routed away from power lines,
fluorescent lighting fixtures and other sources of electrical
interference, such as radios, transmitters, etc.
◆
Make sure that a separate grounded power outlet that provides 100 to
240 VAC, 50 to 60 Hz, is within 2.44 m (8 feet) of each device and is
powered from an independent circuit breaker. As with any equipment,
using a filter or surge suppressor is recommended.
Summary of Contents for TigerSwitch 10
Page 2: ......
Page 20: ...FIGURES xvi...
Page 30: ...ABOUT THE TIGERSWITCH 10 100 1 10...
Page 56: ...MAKING NETWORK CONNECTIONS 4 10...
Page 74: ...ORDERING INFORMATION D 2...
Page 80: ...Glossary 6...
Page 84: ...INDEX Index 4...
Page 85: ......