Segment LEDs
— flash yellow, then change to the color
indicating the position of the Segment switch.
•
Port Status LEDs:
•
10BASE-T and Dual ST LEDs
flash yellow and then
go off. Once testing is complete, these LEDs indicate
port activity.
•
AUI and BNC LEDs
turn green after the power-on
sequence and remain on until a data packet has been
passed successfully. If the BNC port is not termi-
nated, the BNC LED will light yellow and the port
will partition due to excessive collisions.
• Collision LEDs
— turn yellow for a fraction of a sec-
ond, then go off. Once testing is complete these LEDs
indicate network activity.
Refer to Chapter 5, “Troubleshooting,” for more information
about the LEDs.
4.
For TigerStack 3312TA and 3326TA Only
– If you have
purchased one or more Redundant Power Units, connect
them to these devices and to an AC power source now, fol-
lowing the instructions included with the package.
I
NSTALLING
16