Procedure
Models 3314T, 3328T, 3328TELCO, 3306BC, 3306FC
1. To isolate a segment, move the button labeled Segmentation
Enable to the On position (out).
2. Either press the Reset button (using a small, pointed instru-
ment) or power the hub off, then on again.
Models 3312TA and 3326TA
1. Move the 3-position switch to one of the following posi-
tions:
Stack
– Select Stack to connect the segment to the stack via
the inter-repeater bus. The Select LED will be off.
Hub
– Select Hub to isolate the segment from the hub and
to combine it with the other segments in the hub that have
been set similarly, forming a larger segment. The Select
LED will be green.
Isolate
– Select Isolate to completely isolate the segment.
The Select LED will be yellow.
2. Either press the Reset button (using a small, pointed instru-
ment) or power the hub off, then on again.