ELECTRODE CLEANING:
Mix up a solution of 1 part hydrochloric acid to 8 parts water. Submerse the electrode
in this solution.
There will be a reaction as the calcium is dissolved. When the reaction ceases
(about 10 minutes) rinse the electrode in clean water, wipe the brass terminals dry and
check that all calcium has been dissolved. If not, repeat the process with a new solution.
ELECTRODE REASSEMBLY:
Ensure the silicon seal is still in place on the inside circumference of the electrode cap.
Insert the electrode back into the housing and screw on (clockwise) the locking nut.
Plug the electrode lead back on to the electrode terminals and turn on the power to
the chlorine generator.
WATER CHEMISTRY:
Have your water tested regularly. Transport
the test water in an opaque container and
have the test done as soon as possible for the
most accurate results. The following is a list of
recommended water chemistry levels.
CAUTION:
• When working with acid the
use of eye protection and
rubber gloves is strongly
recommended.
• When mixing, add acid to
water, but NEVER water
to acid.
TDS: 2500 ppm
Total alkalinity: 90 – 150 ppm
Chlorine: 1.5 – 2.0 ppm
Cyanuric acid: 40 – 65 ppm
pH: 7.2 – 7.4