background image

SET

CH

kPa

MPa

OUT2

1

2

3

4

OUT1

PRESSURE

Descriptions

UP button

SET button

Unit display

Channel display

DOWN button

kgf/cm

2

bar PSI inHg mmHg

Unit labels

4-digit display

Switch output display

Error Code & Solution

LED display

Contents

Solution

Excess current is 
flowing into the 
switch output of 
OUT1.

Excess current is 
flowing into the 
switch output of 
OUT2.

Supply pressure 
exceeds the 
maximum regulating 
pressure. 

Supply pressure is 
below the minimum 
regulating pressure. 

Pressure is applied 
to a pressure sensor 
during the reset 
operation (a zero 
point adjustment) as 
follows: 
When compound 
pressure is used: 

±

 2.5% F.S. or more.

When pressure other 
than compound 
pressure is used: 

±

5% F.S. or more.

∗ 

After displaying for 
2 seconds, it will 
return to the 
measuring mode. 

Shut off the power 
supply. After 
eliminating the 
output factor that 
caused the excess 
current, turn the 
power supply back 
on.  

Bring the pressure 
back to atmospheric 
pressure and use 
the reset function 
(zero point 
adjustment) again. 

Reduce/Increase 
supply pressure to 
within the regulating 
pressure range. 

Shut off the power 
supply and turn it 
back on. Please 
contact SMC if it 
does not recover.

Internal Circuit and Connection

PSE200-(M)

• NPN open collector 5 o Auto shift 1 input specification

PSE201-(M)

• PNP open collector 5 o Auto shift 1 input specification

+

+12 to 24 VDC

DC (+)

Sensor input: +1 to 5 VDC

DC (–)

N.C.

DC (+)

Sensor input: +1 to 5 VDC

DC (–)

N.C.

DC (+)

Sensor input: +1 to 5 VDC

DC (–)

N.C.

DC (+)

Sensor input: +1 to 5 VDC

DC (–)

N.C.

+

+12 to 24 VDC

Load

Load

Load

Load

Load

DC (+) (Brown)

  Auto shift input (Yellow)

  CH1_OUT1 (Black)

  CH1_OUT2 (White)

 CH2_OUT1 (Gray)

  CH3_OUT1 (Orange)

  CH4_OUT1 (Pink)

  DC (–) (Blue)

1.2 k

7.3 k

Main circuit

DC (+)

Sensor input: +1 to 5 VDC

DC (–)

N.C.

DC (+)

Sensor input: +1 to 5 VDC

DC (–)

N.C.

DC (+)

Sensor input: +1 to 5 VDC

DC (–)

N.C.

DC (+)

Sensor input: +1 to 5 VDC

DC (–)

N.C.

Load

Load

DC (+) (Brown)

  Auto shift input (Yellow)

  CH1_OUT1 (Black)

  CH1_OUT2 (White)

 CH2_OUT1 (Gray)

  CH3_OUT1 (Orange)

 CH4_OUT1 (Pink)

  DC (–) (Blue)

1.2 k

7.3 k

Displays the output status of 
OUT1 (CH1 to CH4), OUT2 
(CH1 only).
Lights up when it is ON. 

Use this button to change the 
mode or set value. 

Use this button to set the mode 
or set value. 

Use this button to change the 
mode or set value. 

Displays the selected channel. 

The selected unit lights up. Use 
unit labels for units other than 
MPa and kPa. 

Main circuit

Load

Load

Load

Displays the measured 
pressure value, content for 
each setting, and error code.

Internal data error.

Internal data error.

Internal data error.

Internal data error.

Please contact SMC. 

16-3-10

Series 

PSE530/200

SHOP ONLINE at www.airlinehyd.com

800-999-7378

Summary of Contents for PSE200 Series

Page 1: ...dapter 48 conversion adapter Mounting screws M3 x 8L Accessory Panel Power supply Output connection cable ZS 26 A Included with the controller Front protective cover Option When only optional parts ar...

Page 2: ...sation Operating Stored 35 to 85 RH No condensation 10 to 500 Hz at whichever is smaller of 1 5 mm amplitude or 98 m s2 acceleration in X Y Z directions for 2 hrs each De energized 980 m s2 in X Y Z d...

Page 3: ...1 5 Gray CH2_OUT1 4 White CH1_OUT2 3 Black CH1_OUT1 2 Blue DC 1 Brown DC Power supply Output connection cable Included 2000 Power supply Output connector 8P PIN no Terminal DC DC CH1_OUT1 CH1_OUT2 CH2...

Page 4: ...nel fitting dimension Applicable panel thickness 0 5 to 8 mm 55 or more 37 5 0 1 0 2 55 or more Waterproof seal Waterproof seal Panel Panel mount adapter 48 conversion adapter Panel Panel mount adapte...

Page 5: ...onnection PSE200 M NPN open collector 5 outputs Auto shift 1 input specification PSE201 M PNP open collector 5 outputs Auto shift 1 input specification 12 to 24 VDC DC Sensor input 1 to 5 VDC DC N C D...

Page 6: ...ure range Applicable pressure sensor Sensor supply pressure 101 to 101 kPa PSE533 10 to 101 kPa PSE531 10 to 101 kPa PSE532 0 1 to 1 MPa PSE530 Pressure Sensor Sensor Range Compound pressure Vacuum Lo...

Page 7: ...al pressures by changing the response time setting Principle The pressure values measured within the response time that is selected by the user are averaged By comparing this average pressure value wi...

Page 8: ...d the set value Switch output 1 2 P1 P2 P3 P4 ON OFF Hysteresis Hysteresis Normally closed Note The hysteresis is set to 3 digits When setting the pressure allow 7 digits or more Note 1 If the hystere...

Page 9: ...the equipment to be set in this mode In the case where OUT1 setting is not required In the case where OUT2 setting is not required OUT1 auto preset For adsorption verification In this mode repeat the...

Page 10: ...MPa OUT2 1 2 3 4 OUT1 PRESSURE SET CH kPa MPa OUT2 1 2 3 4 OUT1 SET SET SET Copy mode Copy mode Selection of the channel to be copied Selection of the channel to be copied to Copy mode or Setting is...

Page 11: ...OUT1 Auto identification mode Auto identification mode ON To measuring mode or On Off CH3 3 Auto shift 4 Auto identification On Off CH2 Displays alternately On Off CH1 On Off CH4 Setting is complete...

Page 12: ...pressure erroneous operation may occur e g in the case of adsorption verification the switch does not turn ON even though the workpiece is being adsorbed or does not turn OFF even though the workpiec...

Page 13: ...To return to the measuring mode press Bottom value blinks Peak Bottom display Press and hold for 2 seconds or longer SET SET SET SET If any buttons other than above are pressed during the peak bottom...

Page 14: ...unctions may occur due to noise from these other lines 4 If a commercial switching regulator is used make sure that the F G terminal is grounded Connection Warning 1 Our multi channel pressure sensor...

Page 15: ...nserted all the way temporarily hold the connector down manually Using pliers snap A into B as shown below so that there is no gap between A and B and secure the connector The A and B portion of the s...

Page 16: ...O D 1 0 to 1 4 1 4 to 2 0 1 0 to 1 4 1 4 to 2 0 Sensor part no PSE510 PSE530 PSE521 PSE520 Brown Black Blue N C 1 2 3 4 F G Regulating Pressure Range Rated Pressure Range 1 Regulating pressure range R...

Page 17: ...3 Do not service machinery equipment or attempt to remove components until safety is confirmed 1 Inspection and maintenance of machinery equipment should only be performed once measures to prevent fal...

Page 18: ...y 3 Drain flushing Remove drainage from air filters regularly Refer to the specifications 4 Shut down before maintenance Before attempting any kind of maintenance make sure the supply pressure is shut...

Page 19: ...rd related to environmental management systems and environmental inspections While promoting environmentally friendly automation technology SMC is also making diligent efforts to preserve the environm...

Page 20: ...chinery Directive contains essential health and safety requirements for machinery as applied to industrial machines e g machine tools injection molding machines and automatic machines Pneumatic equipm...

Page 21: ...d for compliance with CSA Standards and UL Standards at the same time and was approved for compliance with the two Standards The above CSA NRTL C logo is described on a product label in order to indic...

Page 22: ...irmatic Ltda Calle 18 69 05 Apart Aereo 081045 Santa Fe de Bogot Colombia TEL 1 424 9240 FAX 1 424 9260 U K SMC Pneumatics U K Ltd Vincent Avenue Crownhill Milton Keynes MK8 0AN Backinghamshire U K TE...

Page 23: ...ngton Auckland New Zealand TEL 09 573 7007 FAX 09 573 7002 TAIWAN SMC Pneumatics Taiwan Co Ltd 17 Lane 205 Nansan Rd Sec 2 Luzhu Hsiang Taoyuan Hsien TAIWAN TEL 03 322 3443 FAX 03 322 3387 HONG KONG S...

Reviews: