Wiring
Caution
3. Connecting to other series
• Any pressure sensor (SW) can be connected as long as it
generates analog output (1 to 5 V) signal. However, the
pressure range must match.
• SMC pressure sensors, Series PSE510 & PSE520, are also
connectable.
• When connecting to pressure sensors other than the Series
PSE530, connector types will vary depending on the wire core
size of the cable and the outside diameter of the insulation
cover. Refer to the table provided below.
• Refer to the following diagram for connecting Series PSE520 to
the connector.
ZS-26-E
ZS-26-E-1
ZS-26-E-2
ZS-26-E-3
Connector
part no.
Wire core size
AWG24-26 (0.14 to 0.2 mm
2
)
AWG24-26 (0.14 to 0.2 mm
2
)
AWG20-22 (0.3 to 0.5 mm
2
)
AWG20-22 (0.3 to 0.5 mm
2
)
Insulation
cover
O.D.
ø1.0 to 1.4
ø1.4 to 2.0
ø1.0 to 1.4
ø1.4 to 2.0
Sensor part no.
PSE510, PSE530
PSE521
PSE520
Brown
Black
Blue
N.C.
1
2
3
4
F.G.
Regulating Pressure Range & Rated Pressure Range
1. Regulating pressure range: Refers to allowable
pressure range in a pressure setting mode.
• Setting range is between P_1(n_1) to P_4(n_4).
• For Series PSE200, the regulating pressure range and the
setting pressure range that can be displayed are the same.
2. Rated pressure range: Refers to the pressure range
that satisfies the product specifications.
• Pressure range that satisfies the product specifications
(accuracy and linearity) for PSE530.
Caution
( )
There is no shielding wire for
Series PSE510 & PSE530.
Connect the shielding wire to
the frame ground (F.G.) or
F.G. terminal.