background image

®

How to Order

RoHS

M

A

Output specifications

Symbol

OUT1

OUT2

A

NPN

NPN

B

PNP

PNP

C

NPN

Analog (1 to 5 V)

D

NPN

Analog (4 to 20 mA)

E

 Note 2)

PNP

Analog (1 to 5 V)

F

 Note 2)

PNP

Analog (4 to 20 mA)

G

 Note 2)

NPN

External input

 Note 3)

H

 Note 2)

PNP

External input

 Note 3)

Note 2) Made to Order
Note 3)  Can be selected from accumulated 

flow external reset and peak/bottom 
reset.

Option 2

Nil

No bracket

R

With bracket

 Note 7)

Note 7) Each option is not assembled with the 

product, but shipped together.

Option 1

Nil

With lead wire and M8 connector (3 m) 

Note 4)

N

Without lead wire and M8 connector

Note 4) Each option is not assembled with the 

product, but shipped together.

Unit specifications

Nil

Unit selection function

 Note 5)

M

SI unit only

 Note 6)

Note 5) Since the unit for Japan is fixed to SI due to new 

measurement law, this option is for overseas.

Note 6) Fixed unit: Instantaneous flow: L/min, 

Accumulated flow: L

Calibration certificate

Nil

None

A

 Note 8)

Yes

Note 8)  Made to Order: Certificate in 

both English and Japanese

Option/Part No.

When only optional parts are required, order with the part number listed below.

Part no.

Option

Note

ZS-40-A

Lead wire and M8 connector

Length: 3 m

ZS-42-A

Bracket

Mounting screw for PFMC7501/7102 (M3 x 5, 2 pcs.)

ZS-42-B

Bracket

Mounting screw for PFMC7202 (M3 x 5, 2 pcs.)

PFMC 501

04

7

Thread type

Nil

Rc

N

NPT

F

G

 Note 1)

Note 1) ISO228 compliant

Rated flow range

501

5 to 500 L/min

102

10 to 1000 L/min

202

20 to 2000 L/min

Port size

Symbol

Port 
size

Rated flow range

501

102

202

04

1/2

V

V

06

3/4

V

PFMC 

Series

3-Color Display

 

Digital Flow Switch

279

PFM

PFMV

PFMB

PFMC

PF2A

PF3W

PF2D

LFE

IF

PFMC

A

Summary of Contents for PFMC Series

Page 1: ...Current PF2A 5 L min 1 L min Wide range of flow measurement with one product Compared with the current PF2A IP65 Compact Space saving Flow ratio 78 reduction Weight 74 reduction Setting resolution 10...

Page 2: ...dication shows the operating flow rate or residual amount of N2 etc in a gas cylinder Flow control of equipment main line and branch line Applications Remote control is possible with accumulated pulse...

Page 3: ...method Applicable fluid Thermal type MEMS Thermal type MEMS Air N2 Air N2 Argon CO2 Dry air N2 0 1 L min 0 5 L min 1 L min 2 L min 5 L min 5 L min 10 L min Thermal type MEMS Bypass flow type Thermal...

Page 4: ...o 50 C 12 to 24 VDC 10 12 to 24 VDC 10 1 to 10 L min 5 to 50 L min 10 to 100 L min 20 to 200 L min 50 to 500 L min 150 to 3000 L min 300 to 6000 L min 600 to 12000 L min PFMB Digital IP40 2 color LCD...

Page 5: ...5 M SI unit only Note 6 Note 5 Since the unit for Japan is fixed to SI due to new measurement law this option is for overseas Note 6 Fixed unit Instantaneous flow L min Accumulated flow L Calibration...

Page 6: ...25 to 525 L min Displays 0 when value is within 4 to 4 L min range 50 to 1050 L min Displays 0 when value is within 9 to 9 L min range 100 to 2100 L min Displays 0 when value is within 19 to 19 L min...

Page 7: ...a straight section of piping with a length of 8 cm or more If a straight section of piping is not installed the accuracy can vary by approximately 2 F S Straight section means a part of the piping wit...

Page 8: ...or solid state input for 30 msec or longer NPN 1 output Analog 1 to 5 V output type PFMC7 C NPN 1 output Analog 4 to 20 mA output type PFMC7 D Max applied voltage 28 V Max load current 80 mA Internal...

Page 9: ...ctifier Stainless steel 304 4 Sensor chip Silicon 5 Printed circuit board GE4F 6 Gasket HNBR 7 Body Aluminum alloy Anodized 8 Mesh Stainless steel 304 9 Spacer PPS 10 O ring HNBR 11 Holder Stainless s...

Page 10: ...ue Sheath Material Heat and oil resistant PVC Finished outside diameter 4 Symbol Model Port size A B D E F H K L N PFMC7501 7102 Rc1 2 NPT1 2 70 30 60 6 41 2 15 14 26 18 13 6 PFMC7202 Rc3 4 NPT3 4 G3...

Page 11: ...fixed state when starting the system or during maintenance This enables confirmation of the wiring and prevents system errors due to unexpected output For the analog output type when ON the output wi...

Page 12: ...ntents Action OUT1 over current error Load current of 80 mA or more is applied to the switch output OUT1 Eliminate the cause of the over current by turning off the power supply and then turn on it aga...

Reviews: