Fault
Probable cause
Recommended action
O
u
tp
u
t
There is no output.
Wiring failure.
Correct the wiring.
Connector loose.
Check the connector.
Output is unstable.
Foreign matter inside.
Install a filter or mist separator at IN side of product.
If there is foreign matter stuck to the mesh, remove it
completely, taking care not to damage the product.
Piping is connected in the wrong
direction.
Install with the mounting direction corresponding to
the flow direction (arrow indicated on the product).
Pulsation in the flow.
Change to a pump that has less pulsation. Install a
tank to reduce the pressure fluctuation. Change the
piping to elastic piping such as rubber tube.
Air leakage.
Check that seal tape has been applied correctly.
Reconnect the pipes with the specified tightening
torque.
Hysteresis is too narrow.
Increase the hysteresis.
Bu
tt
o
n
The buttons cannot be
operated.
Key-lock mode is activated.
Cancel the Key-lock function. (page