-18-
No.PF
※※
-OMO0008-C
●
Internal circuit and wiring example
When the lead wire with connector designated for the PF2A7 is used, the wire colours will apply as shown in
the diagram.
NPN (2 outputs) type
PF2A7
-
-27
-
Max. 30 V, 80 mA
Internal voltage drop: 1 V or less
PNP (2 outputs) type
PF2A7
-
-67
-
Max. 80 mA
Internal voltage drop: 1.5 V or less