Table. 17 Auto switch block unit
* The auto switch block unit is included in the auto switch unit.
* Auto switch block unit showa the necessary assembly for mounting 1 piece of auto switch to the auto
switch unit.
*Individual part cannot be shipped.
How to replace table unit
【
Disassembling
】
(1) Remove a hexagon socket head cap screw
④
.
【
Reassembling
】
(1) Tighten a rotary unit and a table unit
with a hexagon socket head cap screw
④
.
How to replace rotary unit
【
Disassembling
】
(1) Remove a hexagon socket head cap screw
④
.
(2) Loosen a hexagon socket head cap screw
③
(3) Remove a stopper guide
①
.
【
Reassembling
】
(1) Fit a lever retainer
②
to a shaft chamfered
face, and mount a stopper guide
①
.
At that time, make clearance of around 0.5mm
between a stopper guide and a rotary unit.
(2) Tighten a hexagon socket head cap screw
③
.
At that time, take care not to tighten a lever
Retainer and shaft chamfering surface unevenly.
(3) Tighten table unit and a rotary unit with a hexagon
socket head cap screw
④
.
- 41 -
MDSUA1/3
MDSUA7/20
For reed auto switch
For solid state auto
switch
Combination of reed and
solid state auto switch
Right handed
Left handed
Combination right and
left handed
Combination right and left
handed
Part No: P211070-8
Part No: P211070-9
Part No: P211070-13
Part No: P211060-8
Table unit
Connect a lever retainer to chamfered face
①
Stopper guide
②
Lever retainer
③
Hexagon socket
head cap screw
Rotary unit
④
Hexagon socket
head cap screw
Chamfer