SMC Networks MQML H Series Manual Download Page 3

Application examples

 for a single acting model

Application example 

for a double acting model

Features 4

Recommended Circuit Examples

/

ø4, ø6, ø10, ø16, ø20

(Metal Seal Type/Single Acting)

• Vacuum retraction cylinder
• Single acting, spring return type (Built-in 

springs)

• No exterior leakage (For clean rooms)
• Tubing with a maximum of ø40 (I.D.) is available.

Made to Order

control range of 0.01 N to 200 N

1) When using a solenoid valve, SMC recommends you use the VQ100 

series in which the lubricant in the main valve will not flow out.

2)Do not use a speed controller in the circuit. If it is used, accurate thrust 

control may not be possible because the internal pressure of a cylinder 
will drop. Be sure to employ pressure control for control operations.

Application Examples: For force control responding to a slight pressure fluctuation 

Using 2 MQP cylinders can improve the thrusting 
accuracy of an MQQ and/or MQM double acting metal 
cylinder.
Additionally, equal strength of both extension and 
retracting thrust can be obtained.

Polishing

Fixed base

Example 1) Normal operation

W

(                                  )

VQ100 series

Direct operated 

3 port solenoid valve

Mist separator 
(0.01 m or less) (0.3 m or less)

IR 

(Precision regulator)

Air filter 

(5 m or less)

Example 2) Soft-touch operation

W

Mist separator 

(0.3 m or less)

ITV 

(Electro-pneumatic

regulator)

Air filter 

(5 m or less)

Inspection and mounting of

an electronic component

Coil winding

High-precision linear control

Electronic 
component

Winding

Constant load

Coil spool

Summary of Contents for MQML H Series

Page 1: ...3000 MQML H High speed frequency Series MQP Bore size mm 4 6 10 16 20 Operating pressure range MPa 0 001 to 0 7 Except for moving parts weight 0 01 to 8 0 03 to 19 0 08 to 50 0 20 to 140 0 30 to 200 T...

Page 2: ...oft touching Delicate and precise linear movement control is possible High precision linear control High precision linear control Sliding resistance is drastically decreased because the piston and the...

Page 3: ...nternal pressure of a cylinder will drop Be sure to employ pressure control for control operations Application Examples For force control responding to a slight pressure fluctuation Using 2 MQP cylind...

Page 4: ...erating pressure MPa 0 7 0 6 9 1 19 6 55 0 137 3 219 9 Theoretical Output 7 8 16 8 47 1 117 7 188 5 0 5 6 5 14 0 39 3 98 1 157 1 0 4 5 2 11 2 31 4 78 4 125 7 0 3 3 9 8 4 23 6 58 9 94 3 0 2 2 6 5 6 15...

Page 5: ...6 10 16 20 41 41 46 5 49 52 5 A 38 38 41 5 44 47 5 B 29 36 40 E 9 9 5 5 5 5 5 5 F 22 24 38 47 52 I 3 3 5 5 5 L 16 18 20 25 5 28 M 3 2 3 2 3 5 5 4 5 4 N 6 5 9 9 6 6 7 10 10 4 7 7 OB RA RB M3 x 0 5 M3 x...

Page 6: ...ed use turbine oil class 1 with no additives ISO VG32 Do not use spindle oil or machine oil Caution Lubrication MQP cylinder MQP cylinder Series MQP Specific Product Precautions Be sure to read this b...

Page 7: ...Do not service machinery equipment or attempt to remove components until the safety of the worker is confirmed 1 Inspection and maintenance of machinery equipment should only be performed once measure...

Page 8: ...ld be selected and circuits designed to prevent sudden lurching because there is a danger of human injury and or damage to equipment when this occurs 8 Consider emergency stops Design so that human in...

Page 9: ...he system to zero Only then should you proceed with the removal of any machinery and equipment When machinery is restarted proceed with caution after confirming that appropriate measures are in place...