background image

7

Caution

Model

Tube inside diameter 

(I.D.)

Tubing outside diameter 

(O.D.) (after mounting)

LSP1

1-

첸첸

4

Ø 2 or less

Ø 5.8 or less

Tank

Pump

Be sure to read this before handling the products. Refer to the back cover for safety 
instructions and the “Operation Manual” for handling the products. Please download 
the Operation Manual via our website, https://www.smc.eu

LSP 

Series

Specifi c Product Precautions 2

Piping

1.  Do not apply pressure to the pump. If the pump op-

erates with pressure applied, the repeatability may 
decrease or liquid may leak to the OUT side when 
the pump is off. Tank liquid level must be lower than 
the pump and the OUT side tube end must be high-
er than the tank liquid level. Remove any air bub-
bles in the piping and pump chamber.

The holding force varies by the tubing material. Be 
sure to confirm the holding force of each material 
before operation. After connecting the tubing, please 
do not apply load such as tensile force, compression, 
or bending force.

8. When the tubing is long or according to the operating 

conditions, tubing may thrash about, causing damage 
to the tube inlet of the pump, or the tubing to come 
off or deteriorate. In this case, secure the tubing to 
prevent its uncontrolled movement.

9. If the removed tubing is to be used again, cut off the 

section of the tubing which has been gripped by the 
fitting.

2.  Make sure to remove any air bubbles in the piping 

and pump chamber before use.

3.  Preparation before piping

Before piping is connected, it should be thoroughly blown out 

with air (fl ushing) or washed to remove chips, cutting oil and 

other debris from inside the pipe.

4.  Always tighten threads with the proper tightening 

torque.

When piping the fi tting to the body ported (threaded ports), the 

installation method and tightening torque value may vary de-

pending on the seal structure (shape) or material of the fi tting 

to be used. Check the methods and precautions recommend-

ed by the fi tting manufacturer to be used, and be sure to check 

for leakage. It is customer’s responsibility to verify the compat-

ibility of the fi tting and operating liquid.

The table below indicates the reference value when KQ 2 series 

is used for water.

Model

Thread 

size

Tightening 

method

Tightening 

torque [N·m]

(Reference)

Body ported
(Threaded 
ports)

LSP1

1-

A(B)1

M5

After tightening by hand, 
tighten 1 / 6 to 1 / 4 turn 
with a tightening tool.

0.5 to 0.7

LSP1

1-

C(D)1

0.3 to 0.35

LSP1

1-

A(B)2(3)

M6
1/4-
28UNF

After tightening by hand, 
tighten 1 / 6 to 1 / 4 turn 
with a tightening tool.

0.6 to 0.8

LSP1

1-

C(D)2(3)

0.4 to 0.45

When mounting the pump, tighten it with the proper tightening 

torque shown below. For base mounted, tighten the screw 

surely to the correct torque in the table below after confi rming 

that the O-ring is mounted on the interface properly.

Model

Thread 

size

Proper tightening 

torque [N·m]

Body ported 
(Tube connection 
type)/Base 
mounted, Body 
mounting

LSP1

1−

A(B)4

LSP1

2−

A(B)

M2

0.15 to 0.2

LSP1

1−

C(D)4

LSP1

2−

C(D)

0.1 to 0.15

Body ported
(Threaded ports), 
Body mounting

LSP1

1−

A(B)1(2, 3)

M3

0.4 to 0.6

LSP1

1−

C(D)1(2, 3)

0.2 to 0.25

5. Mount the pump on the horizontal surface.

Applicable model: All models

6.  Remove dust from the pump mounting surface 

completely.

The surface roughness of the mounting surface should be 

Rz3.2 or less.

Applicable model: Base mounted

7.  When connecting tubing to the tube connection type, 

please make sure inserting it straight to the end of 
the tube inlet.
If external force of 1 0 N or more is applied to tube 
inlet, the inlet may become damaged, and leakage 
or breakage could occur.
Select appropriate tubing while referring to the table 
below.

Summary of Contents for LSP1 1 Series

Page 1: ...e 5 to 50 L per shot 50 to 100 L per shot 100 to 200 L per shot Adjustment of dispense volume is possible Stable dispense volume Shut off function Self contained system does not need any priming Repea...

Page 2: ...Diaphragm movement is supported by buffer Stable dispense volume and longer life can be achieved by restricting deformation of the diaphragm 1 2 at 5 to 15 L 2 2 Under SMC s measurement conditions Li...

Page 3: ...nal inspections This product is not designed to be explosion proof so it is not suitable for flammable fluids 5 For stable dispensing we recommend that the coil is mounted vertically facing downward o...

Page 4: ...the table below as reference for the range of the dispensing volume adjusting screw Do not apply excessive torque when rotating the dispensing volume adjusting screw If the screw is tightened too muc...

Page 5: ...Mounting hole Lead wire length OUT port M5 x 0 8 depth 5 M6 x 1 depth 5 1 4 28UNF depth 5 IN port M5 x 0 8 depth 5 M6 x 1 depth 5 1 4 28UNF depth 5 Mounting hole 4 2 4 13 300 20 5 7 3 37 69 32 16 10 7...

Page 6: ...rface dimensions Base Mounted LSP1 2 M2 x 0 4 Screw length 8 stainless steel with spring washer 3 pcs Mounting screws are shipped together with the product Lead wire length Vent port OUT port with O r...

Page 7: ...is not designed to be explosion proof so it is not suitable for flammable fluids 7 Dispense volume will vary depending on the fluid and piping conditions After mounting is complete perform appropriat...

Page 8: ...ody ported threaded ports the installation method and tightening torque value may vary de pending on the seal structure shape or material of the fitting to be used Check the methods and precautions re...

Page 9: ...ng When a crystallized or clotted component is caught between the sealing parts unstable liquid dispensing will occur Take measures to clean such component if necessary Wiring Caution 1 Use electrical...

Page 10: ......

Page 11: ...of SMC products with production equipment for the manufacture of weapons of mass destruction WMD or any other weapon is strictly prohibited 2 The exports of SMC products or technology from one countr...

Page 12: ...e smc hu Ireland 353 0 14039000 www smcautomation ie sales smcautomation ie Italy 39 03990691 www smcitalia it mailbox smcitalia it Latvia 371 67817700 www smc lv info smc lv Lithuania 370 5 2308118 w...

Reviews: