background image

Analyzer (for medical/biochemical)

Ink jet printing

Related to semiconductor/solar cell

Application Examples

Adjusting 
screw

Solenoid

Armature

Return spring

IN side check valve

Body

OUT side check valve

1

Liquid Dispense Pump

 (Solenoid Type)  

LSP 

Series

Adjustment of dispense 
volume is possible.

Dispense volume can be changed by 
adjusting the armature stroke with 
adjusting screw.

Stable dispense volume

Shut-off function

Self-priming makes 
priming unnecessary.

Fluid

4

Dispense volume:

  5  to   50 

μ

L per shot

  50  to 100 

μ

L per shot

100  to 200 

μ

L per shot

Repeatability: 

±

1

 %

1, 

2

Diaphragm movement is supported by 
buffer. Stable dispense volume and 
longer life can be achieved by restricting 
deformation of the diaphragm.

1  

±

2 % at 5 to 15 

μ

L

2

2  Under SMC’s measurement conditions

Liquid leakage due to a siphonic 
phenomenon can be prevented by 
seating with diaphragm. No need to 
install an external shut-off valve 
designed to prevent leakage before 
and after the pump.

Sucks the liquid even if the pump is 
dry.

Water, DI water (Pure water), 
Diluent, or Cleaning fl uid

4   These fl uids should not corrode or 

permeate into the fl uid contact 
materials.

3   Do not apply positive or vacuum pressure to IN or OUT port.

Can be selected from 

PEEK or PP

Can be selected from 

EPDM or FKM

Fluid contact material

Diaphragm, Check valve

Body

Buffer

Diaphragm

IN

3

OUT

3

Summary of Contents for LSP1 1 Series

Page 1: ...e 5 to 50 L per shot 50 to 100 L per shot 100 to 200 L per shot Adjustment of dispense volume is possible Stable dispense volume Shut off function Self contained system does not need any priming Repea...

Page 2: ...Diaphragm movement is supported by buffer Stable dispense volume and longer life can be achieved by restricting deformation of the diaphragm 1 2 at 5 to 15 L 2 2 Under SMC s measurement conditions Li...

Page 3: ...nal inspections This product is not designed to be explosion proof so it is not suitable for flammable fluids 5 For stable dispensing we recommend that the coil is mounted vertically facing downward o...

Page 4: ...the table below as reference for the range of the dispensing volume adjusting screw Do not apply excessive torque when rotating the dispensing volume adjusting screw If the screw is tightened too muc...

Page 5: ...Mounting hole Lead wire length OUT port M5 x 0 8 depth 5 M6 x 1 depth 5 1 4 28UNF depth 5 IN port M5 x 0 8 depth 5 M6 x 1 depth 5 1 4 28UNF depth 5 Mounting hole 4 2 4 13 300 20 5 7 3 37 69 32 16 10 7...

Page 6: ...rface dimensions Base Mounted LSP1 2 M2 x 0 4 Screw length 8 stainless steel with spring washer 3 pcs Mounting screws are shipped together with the product Lead wire length Vent port OUT port with O r...

Page 7: ...is not designed to be explosion proof so it is not suitable for flammable fluids 7 Dispense volume will vary depending on the fluid and piping conditions After mounting is complete perform appropriat...

Page 8: ...ody ported threaded ports the installation method and tightening torque value may vary de pending on the seal structure shape or material of the fitting to be used Check the methods and precautions re...

Page 9: ...ng When a crystallized or clotted component is caught between the sealing parts unstable liquid dispensing will occur Take measures to clean such component if necessary Wiring Caution 1 Use electrical...

Page 10: ......

Page 11: ...of SMC products with production equipment for the manufacture of weapons of mass destruction WMD or any other weapon is strictly prohibited 2 The exports of SMC products or technology from one countr...

Page 12: ...e smc hu Ireland 353 0 14039000 www smcautomation ie sales smcautomation ie Italy 39 03990691 www smcitalia it mailbox smcitalia it Latvia 371 67817700 www smc lv info smc lv Lithuania 370 5 2308118 w...