Design / Selection

Warning

Warning

Warning

1.  Do not use this product in applications which may 

adversely affect human life (e.g. medical equipment 
connected to the human body for drip infusion).

2.  Confi rm the specifi cations.

Give careful consideration to the operating conditions such as 
the application, fluid and environment, and use within the 
operating ranges specifi ed in this catalog.

3.  Do not apply pressure to the pump. If the pump op-

erates with pressure applied, the repeatability may 
decrease or liquid may leak to the OUT side when 
the pump is off.

   Refer to page 7 “Piping, Caution 1 .” for the installation 

position of the pump.

4.  For stable dispensing, please use the product under 

stable operating conditions (suction height, ambient 
temperature, fluid temperature). If air bubbles are 
present in the fluid and the piping material is soft, it 
may influence on the repeatability of the dispense 
volume. Install the pump vertically facing downward 
so that air bubbles in the pump are removed easily. 
It is recommended to degasify the fluid and use 
hard material for piping.
When the piping diameter of the fluid outlet is large, 
repeatability may be influenced by surface tension, 
so it is recommended to use proper piping diameter 
with the installation of a nozzle.

5.  Repeatability

Measure the amount of clear water which is dispensed 10 times 
continuously and convert it to one shot of dispensed volume. 
Repeat this measurement 1 0 times, and indicate the difference 
(%) between the average value of 1 0  sets  of  data  (converted 
value of one shot) and the maximum and minimum values. 
These values are calculated based on SMC measurement 
conditions, so the repeatability accuracy is not guaranteed.

<Variation in SMC measurement conditions> 

  Tank liquid 

level must be lower than the pump and the OUT side tube 
end must be higher than the tank liquid level. Remove any 
air bubbles in the piping and pump chamber.

Ambient/Fluid temperatures: 

±

2

 

°C, IN/OUT side piping 

pressure: 

±

0.1 kPa or less,  Applied voltage: 

±

0.01 V

6. Fluid

Be sure to confi rm the compatibility between the component 
material and the fl uid. Since the compatibility of the fl uid used 
may vary depending on its type, additives, concentration, 
temperature, etc., give suffi cient consideration when selecting 
the material.
If the fl uid contains foreign matter, it may be caught in the seat 
or cause wear on the inside of the pump, causing problems.
Install an appropriate fi lter (strainer) before the pump. As a guide, 
the appropriate fi ltration is approximately 50 

μ

m.

When transferring a coagulable liquid, take measures to prevent 
it from coagulating in the pump.
This product is not designed to be explosion proof, so it is not 
suitable for fl ammable fl uids.

7.  Dispense volume will vary depending on the fluid 

and piping conditions.

After mounting is complete, perform appropriate functional 
inspections.

8.  Maintenance space

The installation should allow suffi cient space for maintenance 
activities.

9.  Ambient environment

Use within the allowable ambient temperature range.
Be sure that the liquid or corrosive gas does not touch the 
external surface of the product.
Specifi cally, do not expose the solenoid to fl uid. This may cause 
short circuit. When touching the wet solenoid, an electric shock 
may occur.

10.  Countermeasures against static electricity

Take measures to prevent static electricity since some fl uids 
can cause static electricity.

11.  Energizing for extended periods of time

If the pump is continuously energised for long periods of time, 
temperature rise due to heat generation of the coil may result 
in reduced performance and shorter service life or adversely 
affect the peripheral device. Therefore, if the pump is energised 
for long periods, take measures to cool the pump by mounting 
a fan to keep the surface temperature at 50

 

°C or less.

When the pump is mounted into a control panel, take measures 
to cool the pump and keep the operating temperature within 
the specifi ed range.

12.  If the product has not been used for long periods 

of time, perform a trial run before use. If the prod-
uct is to remain inactive for long periods of time, 
remove the fl uid from the pump.

13.  Do not touch the pump directly with hands. The coil 

can be hot depending on the ambient temperature 
or energising time. Install a protective cover over 
the valve if it can be touched directly with hands.

14.  Leakage voltage

Voltages caused by leakage current may lead to pump mal-
function.
Leakage voltage: 2 % or less of the rated voltage

Mounting

1.  If equipment does not operate properly, stop operation.

After mounting is completed, confirm that it has been done 
correctly by performing a suitable function test.

2.  For stable dispensing, mount the coil vertically fac-

ing downward so that bubbles in the pump are re-
moved easily.

After releasing air bubbles, mounting orientation is not specifi ed.

3.  Do not use this product in a location where it will be 

subject to vibration or impact. The dispense volume 
may become unstable in the presence of vibration 
at the pump or piping.

4. Do not apply external force to the coil section.

5.  Install and operate the product only after reading 

the operation manual carefully and understanding 
its contents.

Be sure to read this before handling the products. Refer to the back cover for safety 
instructions and the “Operation Manual” for handling the products. Please download 
the Operation Manual via our website, https://www.smc.eu

LSP 

Series

Specifi c Product Precautions 1

Summary of Contents for LSP1 1 Series

Page 1: ...e 5 to 50 L per shot 50 to 100 L per shot 100 to 200 L per shot Adjustment of dispense volume is possible Stable dispense volume Shut off function Self contained system does not need any priming Repea...

Page 2: ...Diaphragm movement is supported by buffer Stable dispense volume and longer life can be achieved by restricting deformation of the diaphragm 1 2 at 5 to 15 L 2 2 Under SMC s measurement conditions Li...

Page 3: ...nal inspections This product is not designed to be explosion proof so it is not suitable for flammable fluids 5 For stable dispensing we recommend that the coil is mounted vertically facing downward o...

Page 4: ...the table below as reference for the range of the dispensing volume adjusting screw Do not apply excessive torque when rotating the dispensing volume adjusting screw If the screw is tightened too muc...

Page 5: ...Mounting hole Lead wire length OUT port M5 x 0 8 depth 5 M6 x 1 depth 5 1 4 28UNF depth 5 IN port M5 x 0 8 depth 5 M6 x 1 depth 5 1 4 28UNF depth 5 Mounting hole 4 2 4 13 300 20 5 7 3 37 69 32 16 10 7...

Page 6: ...rface dimensions Base Mounted LSP1 2 M2 x 0 4 Screw length 8 stainless steel with spring washer 3 pcs Mounting screws are shipped together with the product Lead wire length Vent port OUT port with O r...

Page 7: ...is not designed to be explosion proof so it is not suitable for flammable fluids 7 Dispense volume will vary depending on the fluid and piping conditions After mounting is complete perform appropriat...

Page 8: ...ody ported threaded ports the installation method and tightening torque value may vary de pending on the seal structure shape or material of the fitting to be used Check the methods and precautions re...

Page 9: ...ng When a crystallized or clotted component is caught between the sealing parts unstable liquid dispensing will occur Take measures to clean such component if necessary Wiring Caution 1 Use electrical...

Page 10: ......

Page 11: ...of SMC products with production equipment for the manufacture of weapons of mass destruction WMD or any other weapon is strictly prohibited 2 The exports of SMC products or technology from one countr...

Page 12: ...e smc hu Ireland 353 0 14039000 www smcautomation ie sales smcautomation ie Italy 39 03990691 www smcitalia it mailbox smcitalia it Latvia 371 67817700 www smc lv info smc lv Lithuania 370 5 2308118 w...

Reviews: