-15-
30
50 100 150 200 250 300 350 400 450 500 600 700 800
LEY25
●
●
●
●
●
●
●
●
●
-
-
-
-
-
LEY32
●
●
●
●
●
●
●
●
●
●
●
-
-
-
LEY63
-
-
●
-
●
-
●
-
●
-
●
●
●
●
Model
Storoke
[
㎜
]
*Consult with SMC for the manufacture of intermediate strokes.
*Applicable stroke table
2.2 How to Order
②
Size
25
32
63
③
Motor mounting position
Nil
Top mounting type
R
Right side parallel type
L
Left side parallel type
D
In-line type
④
Motor type
Symbol
Type
Output
[W]
Size
Compatible driver
S2
AC servo motor
(
Incremental encoder
)
100
25
LECSA
□
-S1
S3
200
32
LECSA
□
-S3
S4
400
63
LECSA2-S4
S6
AC servo motor
(
Absolute encoder
)
100
25
LECS[B/C/S]
□
-S5
S7
200
32
LECS[B/C/S]
□
-S7
S8
400
63
LECS[B/C/S]2-S8
T6
100
25
LECSS2-T5
T7
200
32
LECSS2-T7
T8
400
63
LECSS2-T8
⑤
Lead
[mm]
symbol
LEY25 LEY32 LEY63
A
12
16(20)
20
B
6
8(10)
10
C
3
4(5)
5
L
-
-
-(2.86)
⑥
Stroke
[mm]
30
30
to
to
800
800
⑧
Motor option
Nil
Without option
B
With lock
⑨
Rod end thread
Nil
Rod end female
thread
M
Rod end male
thread
(1 rod end nut included)
⑩
Mounting
Symbol
Type
Motor mounting
Parallel
In-line
Nil
Ends tapped
/Body bottom tapped
●
●
L
Foot
●
-
F
Rod flange
●
●
G
Head flange
●
-
D
Double clevis
●
-
⑪
Actuator cable type
Nil
Without cable
B
Standard cable
R
Robot cable
(
Flexible cable
)
⑫
Cable length [m]
Nil
Without cable
2
2
5
5
A
10
⑬
Driver type
Compatible driver
Power supply
voltage [V]
Nil
Without driver
A1
LECSA1-S
□
100 to 120
A2
LECSA2-S
□
200 to 230
B1
LECSB1-S
□
100 to 120
B2
LECSB2-S
□
200 to 230
C1
LECSC1-S
□
100 to 120
C2
LECSC2-S
□
200 to 230
S1
LECSS1-S
□
100 to 120
S2
LECSS2-S
□
200 to 230
LECSS2-T
□
200 to 240
⑭
I/O cable length [m]
Nil
Without cable
H
Without cable
(Connector only)
1
1.5
* Motor cable and encoder cable are included.
(Lock cable is also included if motor option
“With lock” is selected.)
* Common to encoder / motor / lock cable
* Mounting bracket is shipped together, (but not assembled).
* When mounting styles are [Rod/Head f lange] or [Ends tapped] with horizontal cantilever,
use it within the Following stroke.
・
LEY25:200 or less
・
LEY32:100 or less
・
LEY63:400 or less
* In case of [Double clevis], use the actuator within the f ollowing stroke limit.
・
LEY25:200 or less
・
LEY32
:
200 or less
・
LEY63:300 or less
* “G” Head f lange is not available f or LEY32
LEY
B
A1
200
2
-
S3
32
- S
②
③
④
⑤
⑦ ⑧ ⑨
⑪ ⑫
⑭
⑬
⑥
⑩
①
⑦
Dust and drip proof option
《
Only available for LEY63
》
記号
LEY25/32
LEY63
Nil
Without
option
Equivalent to
IP5x
(
Dust proof
)
P
-
Equivalent to IP65
(Dust and drip proof)
/
with
Port for breath
*The values shown in ( ) are the lead f or
top mounting, right/lef t side parallel types.
(Equivalent lead which includes the pulley ratio)
①
Accuracy
Nil
Basic type
H
High precision type
•
∗
When the driver type is selected, the cable is
•included. Select cable type and cable length.
•Example)
•S2S2: Standard cable (2 m) + Driver (LECSS2)
•S2 : Standard cable (2 m)
•Nil : Without cable and driver