- 24 -
24V
Driver
0V
Power supply
5. CN1: Power supply plug
5.1 Power supply plug specifications
Power supply plug
【
Power supply connector
】
LEC-D-1-1
(
FK-MC0.5/5-ST-2.5
:
Manufactured by Phoenix Contact
)
5.2 Electric wire specifications
Item
Specifications
Applicable wire size
(Single line, stranded wire, stranded wire
with bar terminal (without insulation sleeve))
AWG20 (0.5mm
2
)
Cable sheath O.D. ø2.0mm or less
The rated temperature for the insulation coating:
60
o
C or more
Stripped section length
Please insert only the peel line part when insert the electric wire in the power plug.
Caution
Multiple electric wires should not be connected to one terminal.
Arrange wiring so that conductors of each terminal do not contact other lines.
5.3 Wiring of power supply plug
Connect the power supply plug to the 24 VDC driver power supply according to instructions (1) (2) and
(3) and then, insert it into the CN1 connector of the driver.
(1) Wiring of the power supply
Connect the positive of the 24 VDC driver power supply of the driver to the C24V, M24V and EMG
terminal of the power supply connector, and connect the negative of that power supply to the 0V terminal.
0V
M24
V
C
24
V
E
MG
B
K
R
LS
Terminal
Function
Descriptions
0V
Common power (-)
The negative common power for M24V, C24V, EMG
and BK RLS.
M24V
Common power (+)
The positive power for the actuator motor to be supplied
via the driver.
C24V
Control power (+)
The positive control power.
EMG
Stop signal (+)
The positive power for Stop signal.
(Motor is can operate to connect the 24V.)
BK RLS
Lock release (+)
The positive power for lock release.
BK RLS
EMG
C24V
M24V
0V
Power supply plug
●
Open/Close lever
Press these levers with the special driver,
etc. and insert electric wires into the
entries.
Phoenix special driver (recommended)
(Part no: SZS0.4 x 2.0)
Wire entry
(External stop circuit)
8mm