- 42 -
No.JXC
※
-OMT0007-D
●
Byte 18, 19: Trigger LV
Byte
Signal name
Description
Input range
Min. unit
18
Trigger LV
8,
12)
1%
19
●
Byte 20 - 35: Not available
[Output data length: When
36 Bytes
is selected
]
●
Byte 4, 5: Operation method/Start flag
Byte
Bit
Signal name
Description
4
0
Start flag
Data transmission flag during numerically instructed operation.
Turn OFF during waiting for transmitting. Turn ON when
transmitting numerical data to the controller. (
8,
9,
10)
1-7
(Unused)
Set always OFF(0)
5
0-1
Operation modes
1: ABS (Absolute) , 2: INC (Relative) (
8,
11)
2-7
(Unused)
Set always OFF(0)
●
Byte 6, 7: Speed
Byte
Signal name
Description
Input range
Min. unit
6
Speed
1 to Basic parameters
"Maximum speed"
8,
12
1 mm/s
7
●
Byte 8-11: Target position
Byte
Signal name
Description
Input range
Min. unit
8
Target position
Basic parameter
"Stroke(-)" - "Stroke (+)" (
6,
8,
12)
0.01mm
9
10
11
●
Byte 12, 13: Acceleration
Byte
Signal name
Description
Input range
Min. unit
12
Acceleration
1 to “Max ACC/DEC” of the basic
parameter (
8,
12)
1 mm/s
2
13
●
Byte 14, 15: Deceleration
Byte
Signal name
Description
Input range
Min. unit
14
Deceleration
1 to “Max DEC” of the basic parameter
(
8,
12)
1 mm/s
2
15
6 Refer to
21. Handling of sent/received data
(P.
.
8 Change the numerical data input flag and the numerical data only when the start flag is OFF.
If the numerical data input flag or the numerical data are changed when the start flag is ON, it may
lead to unexpected operation.
9 Turn ON the start flag from OFF only when stopped. If the numerical data input flag or the numerical
data is changed while operating, it may lead to unexpected operation.
10 To avoid unintentionally changing the numerical data, it is recommended to turn OFF the start flag
after starting an operation.
11 Do not input numbers other than [1(ABS)] and [2(INC)].
12 The actuator model determines the limit for the input values. Please refer to the manual of the
actuator for more details.