4-4. Alarm function 

If abnormal functioning occurs during operation, the user is alerted by the external output signal or LED operation.

 

Alarm name 

Status of the parallel I/O signals 

ON 

LED 

LED blinking 

(Blinks at 1Hz) 

Operation after alarm 

+ ions are generated 

Product 

How to release error 

after recovery 

Power supply 
failure 

Error signal OFF (Break contact) 

Discharge signal OFF(Albeit contact) 

Maintenance signal OFF (Albeit contact) 

PWR 

(Green) 

Stop 

When the connected power 
supply voltage is outside of 
the specification. 

Auto 

Incorrect 
high voltage 

Error signal OFF (Break contact) 

Discharge signal OFF(Albeit contact) 

Maintenance signal OFF (Albeit contact) 

ION/HV 

(Red) 

Stop 

When abnormal high voltage 
is discharged. 

Reset signal input   

Turn the power on 

again 

Output signal 
over current 

ION/HV 
(Green) 

Continue 

Over current is present on 
the output circuit    and 
protection circuit is activated 

Auto 

CPU ALM 

Error signal OFF (Break contact) 

Discharge signal OFF(Albeit contact) 

Maintenance signal OFF (Albeit contact) 

PWR (green) 

Stop 

When CPU operates 
abnormally due to noise etc. 

Turn the power on 

again. 

ION/HV (red) 

NDL (green) 

Maintenance 
warning 

Maintenance signal ON(Albeit contact) 

NDL 

(Green) 

Continue 

When static neutralization 
performance is reduced due 
to contamination, wearing or 
breakage of emitters. 

Input ion discharge 

signal 

Turn off the power and 

then on again. 

 

1) Power supply failure 

When the power supply connected to the product is not within the range of 24 V +/-10%, the error signal 

will  be  turned  OFF  (ON  when  it  is  normal),  the  discharge  signal  will  be  turned  OFF,  and  the  PWR  LED 
(green) will flash to indicate the error. 

When the failure occurs, ion generation will be stopped. 
To resolve the error, reset the product automatically by connecting a power supply which provides a power 

supply voltage of 24 V +/-10%. 

 

2) Incorrect high voltage 

When  incorrect  emitter  discharge  is  detected  during  operation,  the  error  signal  will  be  turned  OFF  (ON 

when it is normal), the discharge signal will be turned OFF, and the ION/HV LED (red) will be ON to indicate 
the error. 

When the failure occurs, ion generation will be stopped. 
The incorrect electric discharge could be caused by condensation or dust on the emitters. 
To resolve the error, input the reset signal or supply power again after remedying the cause of the incorrect 

electric discharge. 

 

3) Output signal over current 

When excessive current flows to the output circuit, the current will be limited to protect the circuit and the 

ION/HV LED (green) will flash to indicate the error. 

The product operates even when excessive current is generated in the output circuit. 
To resolve the error, reset the product automatically by reducing the current to the output circuit down to 40 

mA or less. 

 

4) CPU error 

When the CPU makes an abnormal operation due to noise or other reasons, the error signal will be turned 

OFF (ON when it is normal), and the PWR LED (green), ION-HV LED (red) and NDL LED (green) will flash to 
indicate the error. 

When the failure occurs, ion generation is stopped. 
To prevent noise, perform the following actions and take countermeasures. 

1. Keep the product away from sources of noise.   
2. Route the power line and cable of the product separately. 
3. Install a noise filter to the power supply of the product.   

To resolve the error, supply power again after fixing the cause of the error. 

 

5) Maintenance warning 

The  maintenance  signal  is  ON  when  static  electricity  neutralization  performance  has  decreased  due  to 

contamination, wear or damage to the emitters. The NDL LED (green) will turn ON to indicate that cleaning 
or replacement of the emitters needs to be performed. 

The product continues operation even when the maintenance warning has been generated. 
When emitters are contaminated, the error can be solved by cleaning them. However, when they are worn 

out or damaged, it is necessary to replace the emitter assembly.   

To resolve the error, input the discharge stop signal or supply power again after remedying the cause of 

the error. 

When  the  female  threads  for  piping  option  is  used,  the  maintenance  signal  will  turn  ON  if  the  nozzle 

pressure increases (causing the ion generation to decrease) due to the nozzle type.

 

 

Summary of Contents for IZN10E Series

Page 1: ...Traffa Schneller Abbau statischer Elektrizit t Bedienungsanleitung D senausf hrung Serie IZN10E...

Page 2: ...Doc no IZ OMV0005 1 PRODUCT NAME Ionizer Nozzle type MODEL Series IZN10E Series...

Page 3: ...llation 13 3 1 2 Ionizer Body Installation 14 3 2 Wiring 17 3 2 1 Connection Circuit 17 3 2 2 Wiring of the power supply cable 19 3 2 3 Ground connection 19 3 2 4 AC adapter 19 3 3 Timing chart 20 4 F...

Page 4: ...equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly...

Page 5: ...e failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are exclud...

Page 6: ...inspection and wiring To avoid applying unreasonable stress to the connector and one touch fitting ensure any bends in the cable or air tubing are greater than the minimum bending radius If the cable...

Page 7: ...onfirm the effect of the static neutralization after installation 1 Before wiring ensure that the power supply capacity meets the specification and that the voltage is within the specification 2 To ma...

Page 8: ...se damage to this product These may cause an electric shock fire etc a Areas where ambient temperature exceeds the operating temperature range b Areas where ambient humidity exceeds the operating humi...

Page 9: ...ized this may cause an electric shock or accident If the cartridge assembly is removed while compressed air is supplied the cartridge assembly will shoot out If cartridges are not securely mounted to...

Page 10: ...5 to 0 15 MPa Bender tube nozzle IZN10 G X205 0 05 to 0 15 MPa Long nozzle IZN10 G X226 0 05 to 0 15 MPa Fitting Applicable tube O D 6 mm Tube O D 6 mm I D 4 mm Note 1 0 05 to 0 1 MPa Fitting Applicab...

Page 11: ...cket IZN10E CP Z Symbol Type Nil 3m Z 10m IZN10E CP 01 X13 Symbol Type 01 1m 20 20m IZN10 B1 Symbol Type B1 L bracket B2 Pivoting bracket B3 DIN rail mounting bracket Fixed mounting Pivot mounting Man...

Page 12: ...w rate nozzle 11 Female threads for piping Rc1 8 Symbol Type 06 6 Metric size 07 6 35 1 4 inch size 16 6 Metric size elbow 17 6 35 1 4 inch size elbow IZN10E Input Output specifications A00 P Symbol T...

Page 13: ...s the ionizer External input and output cannot be used when the AC adapter is being used 2 Procedures to Operation IZN10E Mounting pitch Mounting stations Symbol Pitch ES 17 4mm Symbol Stations 2 2 st...

Page 14: ...of the emitter For cleaning or replacing the emitter as shown in drawing step 1 to 3 below remove the power cable and release the cartridge assembly lock by rotating the locking knob to the FREE posit...

Page 15: ...les When installing the product use M3 hexagon socket head cap screws The screws should be prepared by the user Referring to the figure below affix the product using screws of optimum length M3 screw...

Page 16: ...holes If the elongated holes are used the flat washers included with the bracket must be used The mounting screws should be prepared by the user Refer to Dimensions section for details Mounting angle...

Page 17: ...n socket head cap screws M3 x 6 and flat washers included with bracket Refer to Dimensions section for details Tightening torque 0 61 to 0 63 Nm c Fixing to the DIN rail Place the DIN rail in the groo...

Page 18: ...minal is not grounded the Ionizer will not be able to achieve the optimal offset voltage ion balance Connection circuit NPN Input Output Be sure to ground 24V 24V 24V 24V Power supply 24 VDC 24V 0V F...

Page 19: ...e Discharge stop signal Pink Reset signal Grey External switch signal 1 Light blue External switch signal 2 White Discharge signal Purple Error signal Yellow Maintenance signal 24V 24V 24V Be sure to...

Page 20: ...Albeit contact The signal is ON while the product is discharging 6 Purple Error signal OUT Break contact The signal is OFF when the power supply high voltage or CPU is abnormal The signal is ON green...

Page 21: ...OFF when not normal ON OFF Maintenance signal ON OFF External switch signal 1 ON OFF External switch signal 2 ON OFF Input 24 VDC power supply ON OFF Discharge stop signal Stopped when OFF ON OFF Rese...

Page 22: ...on it is indicated by the maintenance signal and LED It is recommended to clean the emitters when the maintenance alarm is generated or every two weeks The cleaning frequency varies depending on the e...

Page 23: ...greater The cleaning kit has a felt pad and a rubber grindstone Choose the felt pad or rubber grindstone depending on the level of contamination to effectively clean the emitters 5 The procedure for m...

Page 24: ...e arrow Take care with the emitter when pulling the cartridge assembly 4 Hold the emitter assembly which is mounted to the cartridge assembly using tweezers and pull out in the direction of the arrow...

Page 25: ...ge signal will be turned OFF and the ION HV LED red will be ON to indicate the error When the failure occurs ion generation will be stopped The incorrect electric discharge could be caused by condensa...

Page 26: ...on an electrified plate dimensions 150 x 150mm electrostatic capacity 20pF defined by ANSI standard ANSI ESD STM3 1 2006 Use this data as a guideline for selection as the performance data may vary de...

Page 27: ...Doc no IZ OMV0005 26...

Page 28: ...Doc no IZ OMV0005 27...

Page 29: ...ergy saving nozzle IZN10E 01 06 07 High flow rate nozzle IZN10E 02 Ground terminal Note Note 2 x M3 x 0 5 depth 10 M3 x 0 5 depth 4 Note Note Dimensions of the area shaded on page 5 Mounting 3 mm A 01...

Page 30: ...Doc no IZ OMV0005 29 mm Models B C D IZN10E 16 22 16 11 5 IZN10E 17 24 5 18 5 12 Width across flats 12 16 17 One touch fitting Elbow IZN10E Female threads for piping IZN10E 11...

Page 31: ...ccessory 2 x Hexagon socket head cap screw M3 x 16 Accessory Pivoting bracket IZN10 B2 M o u n t in g a n g le a d ju s t a b le r a n g e M o u n t i n g a n g l e a d j u s t a b l e r a n g e Mount...

Page 32: ...0005 31 Pivot mounting Inward mounting DIN rail mounting bracket IZN10 B3 Accessory M o u n t in g a n g le a d ju s t a b le r a n g e Mounting angle adjustable range 40o 2 x Hexagon socket head cap...

Page 33: ...t Output signal IZN10E CG1 Included NPN IZN10E CG1 P Included PNP IZN10E CG2 Not included NPN IZN10E CG2 P Not included PNP 105 Nominal cross section O D Brown Blue Orange Pink White Purple Yellow Gra...

Page 34: ...directive 2014 30 EC Stainless steel Tungsten Material Weight of the body Weight of the bracket ABS Stainless steel Impact resistance 100m s2 70g 70g 75g 30g Effective static neutralization distance 2...

Page 35: ...ue to bending chipping or wear of the emitter Examine the emitter tip with a magnifier Replace the emitter referring to 4 3 Replacement of the emitter assembly 10 Green NDL LED is ON 1 Dust or dirt on...

Page 36: ...a Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com NOTE Specifications are subject to change without prior notice and any obligation on the part of the m...

Page 37: ...4 D 91522 Ansbach Tel 49 0 981 48 78 66 50 Fax 49 0 981 48 78 66 55 mail traffa de www traffa de Zentrale TBT Technisches B ro Traffa e K Theodor Heuss Str 8 D 71336 Waiblingen Tel 49 0 71 51 604 24...

Reviews:

Related manuals for IZN10E Series