background image

 

 

UNITED Static Control Products Inc.                  Telephone: 719 676 3928 

Page 

1

 of 

3

 

 

ElectraFlow HDG-600 

 

Hand Held Static Neutralizing Air Blow-Off Ionizer

 

Specifications and Installation

 

 
PRODUCT OVERVIEW: 

The HDG-600 Hand Held Ionizing Air Blower is an instrument that provides a 

concentrated flow of balanced ions in conjunction with compressed air to eliminate static, remove dust or 
dry a targeted area or object. The instrument is ISO manufactured to exacting specifications issued by 
United Static Control Products Inc. The HDG-600 is robust, well made and suitable for a multitude of 
applications including delicate electronic products, electronic assembly line items, medical manufacturing, 
and more. The HDG-600 includes the gun assembly, hoses and a heavy duty high voltage transformer 
designed to be powered by a standard, grounded 120 VAC (USA style) plug. Note: 220 volt models are 
available as an option.  This high voltage power source is used to create a balanced stream of negative 
and positive ions from the emitter pin inside the nozzle (located on the hand held gun assembly). The flow 
of the balanced ions overwhelms and neutralizes electrostatic accumulation. The HDG-600 should be 
used by trained personnel only.

 

  

Uses include:

 

 

Eliminating static from items that are used in or near static sensitive products. 

 

 

Eliminating dust or dirt due to static attraction

 

 

The misalignment of small parts due to electrostatic charging

 

 

The undesirable adhesion of plastic films, dirt, and debris due to electrostatic charging 

 

Mechanical Properties

 

Operating Voltage 

 

110V / 60Hz standard, 220V / 50Hz optional

 

Current Consumption 

 

< 0.8 Amp 

 

Operating Temperature

 

32

o

 F. - 122

o

 F. (0 ~50°c)

 

Construction

 

Cast aluminum handle, steel nozzle, tungsten emitter

 

Air pressure

 

15 to 100 psi

 

Effective distance from target

 

4 to 36 inches

 

Weight: gun, power supply, 
hoses

 

11 lbs.

 

RoHS Compliant

 

EC directive 2015/863 RoHS 3 

 

  

Decay Test Results / Other Pertinent Data

 

Testing Condition @ <30% rH and 71.2

o

 F. @ 40 PSI. Testing per ANSI / ESD SP.3.3 

 

Operating Voltage: 110V/220V, Testing Voltage: 1kV to 100 V

 

Distance

 

  

6"

 

12"

 

24"

 

Decay time

 

positive

 

1.2s

 

2.4s

 

3.8s

 

negative

 

1.3s

 

2.4s

 

3.9s

 

Offset voltage

 

< +/- 35 volts typical

 

  

 

Reviews: