![SMC Networks IZN10 Series Operation Manual Download Page 15](http://html.mh-extra.com/html/smc-networks/izn10-series/izn10-series_operation-manual_1299609015.webp)
4-3.Wiring table
Cabl
e col
or
Necessity
of wiring
Signal name
I/O
Specification
No.
- 15 -
1 Brown
Power
24
V
―
○
―
2 Blue
Power
supply GND
―
―
○
3 Orange
Discharge
stop signal
Input
When the signal is turned off, discharge stops.
○
When the signal is turned on and then off, the
error signal is reset.
4 Pink
Reset
signal
Input
When the signal is turned off: Continues
normal operation.
5 White
Discharging
signal
Output
The signal holds ON during discharge
The signal is turned off when error happens.
6 Purple
Error
signal Output
7 Yellow
Maintenance
signal
Output
The signal is turned on when maintenance is
due.
8 Gray
External switch
signal 1
Input
When the signal is turned on, discharge stops.
Light
blue
External switch
signal 2
9
Input
When the signal is turned on, discharge stops.
.
・
Necessity of wiring
○
: Wiring necessary to operate the product
・
In addition to the above wiring, provide class D grounding to the metal (shaded) part around the external
face of the product. If the grounding is not provided or is provided improperly, specified charge elimination
capability is not available. Also, the maintenance signal is turned on.
・
Input signal
NPN: The signal is turned on when the product is connected with the power supply GND, and turned off when
disconnected.
PNP: The signal is turned on when the product is connected with the 24 V power supply, and turned off when
disconnected.
・
Output signal
NPN: Signal ON when a output transistor is energized (with the power supply GND at the inside of the
product) and OFF when de-energized.
PNP: Signal ON when a output transistor is energized (with the 24 V power supply at the inside of the
product) and OFF when de-energized.