![SMC Networks ITV SEN DUX02357 Series Operation Manual Download Page 50](http://html1.mh-extra.com/html/smc-networks/itv-sen-dux02357-series/itv-sen-dux02357-series_operation-manual_1299563050.webp)
IN19856
- 50 -
Rev 2
New ITVs come from the factory preconfigured with a unique MAC address which matches the MAC
address printed on the label of the ITV. New ITVs have a preset static IP address of 192.168.1.20.
Use this IP address initially to access the ITV web page.
Both MAC addresses and IP addresses must be unique on a network. The factory sets the same
static IP address for
all
ITVs; therefore, the IP address
may need to be changed
as part of the setup
process. The IP address change procedure is discussed in this section.
Connection and Power Up
In order to initially access the ITV web page, you will need the following items
1.
One (1) power cable (with a 5-pin female M12 A-Coded connector).
2.
One (1) Ethernet cable (with a 4-pin male M12 D-Coded connector on one end and a
standard LAN Ethernet cable plugin connector (RJ45) on the other end).
3.
A PC with a LAN port. The PC is either directly connected to the ITV using the Ethernet
cable in item 2, or it may be connected to the ITV via a separate cable and switch.
4.
Web browser installed on the PC. Internet Explorer (IE 9 or later), Chrome, or Firefox are
supported.
Connect the Ethernet
cable to the “Bus In” port of the ITV. Connect the LAN connector to your PC
LAN port or switch.
Turn on the PC (and switch, if used).
Connect the power cable to a 24 VDC power supply and to the ITV
Turn on the 24 VDC power supply.
The ITV should power up, the Power LED should be solid green, and the MS LED should be flashing
green. If this does not occur, turn off the 24 VDC power supply or disconnect the ITV power cable.
Verify all connections.