Setting (Common to ZSE50F/ISE50 and ZSE60F/ISE60)
Auto preset (Example: Adsorption Confirmation)
Work 1
Work 1
Work 2
Work 2
= A -
= B +
Work n
Work n
High
Vacuum
Max.A
ON point
OFF point
Min.B
Atmosphere
Suction
Not adsorption
1. Auto preset mode
2. Preparation of auto preset
3. OUT1 auto preset
SET
4. Preparation of auto preset
5. OUT2 auto preset
SET
SET
SET
Select auto preset mode as the
initial setting mode. Press the
SET button and hold it until "RP1"
appears on the display.
Prepare the equipment to be set
while "RP1" is displayed.
If OUT1 setting is not required,
press
the
and buttons simul-
taneously to skip to "RP2".
Repeat vacuum and break several
times while "AIL" is displayed. The
optimum set point value is deter-
mined automatically.
Change the vacuum nozzle or
other conditions of the work piece
and supply vacuum pressure. If
OUT2 setting is not required,
press the
and
buttons simul-
taneously to skip to the meas-
urement mode.
Repeat vacuum and break several
times while "AIL" is displayed. The
optimum set point value is deter-
mined automatically.
A - B
4
A - B
4
Press the SET button.
Press the SET button.
Press the SET button.
Press the SET button to
complete calibration.
ON point
OFF point
Max.A: Maximum pressure value when work piece is vacuumed.
Min.B : Maximum pressure value when work piece is not vacuumed.
15