-33-
No.PS
※※
-OMX0002
∗
: IO-Link mode can provide the communication function.
∗
: Refer to page
for details of the diagnostic information.
Press the
button to set.
Return to function selection mode.
[F 0] Display units, switch output specifications and diagnostic information selection function completed
●
Available display unit and minimum set value
Unit
ZSE20CF
ZSE20C
ISE20C
ISE20CH
MPa
0.001
0.001
0.001
0.001
kPa
0.1
0.1
1
1
kgf/cm
2
0.001
0.001
0.01
0.01
bar
0.001
0.001
0.01
0.01
psi
0.02
0.01
0.1
0.2
InHg
0.1
0.1
-
-
mmHg
1
1
-
-
Setting of diagnostic information selection
It is possible to set the condition in which the diagnostic information
of the process data can be transferred to the upper devices such as
a master.