1.
Application
This instrument aims at controlling pressure of air lines.
2.
Specifications
Model IR2000-A
IR2010-A
IR2020-A
Max. supply pressure
[ MPa]
1.0
Min. supply pressure
[MPa]
(Note 1)
Set pr 0.05
Set pressure range
[MPa]
0.005 to 0.2
0.01 to 0.4
0.01 to 0.8
Sensitivity
(Note 2)
within 0.2% of the full span (F.S.)
Repeatability
(Note 3)
(Note 2)
/- 0.5% of the full span (F.S.)
Air consumption
(Note 4)
[L/min(ANR)]
1.0 or less
[Measuring conditions: supply pressure 1.0 MPa, set pressure 0.2 MPa]
Ambient temp. and
Fluid temperature
[
O
C]
Standard product: -5 to 60
With digital pressure switch: 0 to 50
(No freezing)
Port size
1/4
Pressure gauge port
size
1/8 [2 ports]
Weight [kg]
(
Note 5)
0.23
(Note 1) When there is no flow rate on the outlet side. Maintain the minimum supply pressure
(set pr 0.05MPa).
(Note 2) Full span indicates the maximum set pressure of the product. (e.g.IR2000-A: 0.2MPa)
(Note 3) Other characteristics such as aging deterioration and temperature characteristics are not
included.
(Note 4) Air is released to atmosphere all the times.
(Note 5) Excluding accessories.
-7-
Summary of Contents for IR2000-A Series
Page 14: ...8 Dimensions 13...