background image

 

 

 

7.Countermeasures for failure 
 

 

Warning 

 
 

Avoid use when failure is not solved. 

 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

-9- 

Phenomenon   

Cause   

Countermeasures   

Too  much  flow  from  exaust 
port 

Dust  attach  supply  port  or 
exaust port 

Disassemble and clean. 
(If flawed, replace the part.) 

Broken diaphragm 

Replace diaphragm 

No  signal  even  if  input 
signal is applied 

Pressure leak due to loosen 
screw 

Tighten screw 

Restrictor open too much 

Decrease  open  degrees  of 
restrictor, and lock. 

Broken diaphragm 

Replace diaphragm 

Bad characteristic 

Valve 

stem 

length 

is 

changed due to loosen lock 
nut 

Readjust 

into 

optimum 

valve, and lock. 

Plugged restrictor 

Disassemble and clean 

Deformed diaphragm 

Replace diaphragm 

 

Summary of Contents for IL100

Page 1: ...No IL01 OM00006 B PRODUCT NAME BOOSTER RELAY MODEL Series IL100...

Page 2: ...r your Safety 1 2 1 Outline 3 2 Specification 3 3 Structure and the Operation Principle 3 4 4 Transportation and Storage 5 5 Precautions in Using 6 6 Maintenance 7 8 7 Countermeasures for Failure 9 8...

Page 3: ...guring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembly operation and ma...

Page 4: ...roduct or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product 3 Prior to using SMC p...

Page 5: ...0 Port size Rc1 4 Rc3 8 Mass 560g 3 Structure and the operation principle Input force from the instrument enters to the input chamber and act to diaphragm A This works against the force generated by d...

Page 6: ...LAY DIAPHRAGM A PRESSURE IN FORCE N 1 EQUIVALENT SPRING m N MAIN VALVE Pa M PRESSURE Pa DIAPHRAGM B FORCE N m DISPLACEMENT Pa S SUP ADJUSTABLE NEEDLE VALVE NEEDLE VALVE IN DIAPHRAGM A INPUT CHAMBER DI...

Page 7: ...t from dust Avoid taking out of the bag just before piping even after unpacking 4 If the product is kept unpacking for a certain period select a place where there is no moisture nor corrosive gas Whil...

Page 8: ...ow direction of the air flow when piping 5 The needle valve is opened for 3 4 turn and locked No adjustment is necessary except when the control system is unstable 6 Opening the needle valve delays th...

Page 9: ...wing item When disassemble pay attention in order not to damage diaphragm in the case of diaphragm stick to body To re assemble ensure no foreign matter inside product and pay attention for air path p...

Page 10: ...th Main valve as shown below is adjusted the length by screw and fixed with lock nut To adjust length loose lock nut For the main valve length adjustment make longer when output is low to input signal...

Page 11: ...e part Broken diaphragm Replace diaphragm No signal even if input signal is applied Pressure leak due to loosen screw Tighten screw Restrictor open too much Decrease open degrees of restrictor and loc...

Page 12: ...ing Spare Drawing No Symbol 1 A2017 A2017 A2017 NBR A2017 A2017 RESINIUM 1 26100 1 261017 261015 261014 261012 261010 26108 26109 2 Spring SUS304W 1 26105 3 NBR 1 KA00085 JIS B2401 P6 4 NBR 1 KA00069...

Page 13: ...No IL01 OM00006 B 11...

Page 14: ...1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the pa...

Reviews: