- 5 - 

2. Handling Precaution

 

Air Supply 

   

Caution 

1. Compressed air supply capacity. 

 

Air source, which have supply capacity more than "required 
outlet air flow rate (dry air flow rate) + purge air flow rate" is 
required. See the purge air flow rate diagram on the catalog 
for the purge air flow rate. 

 

2. Chemical substances, which have an adverse 
effect on the product.

 

The  chemical  substances  stated  in  the  table  below  can 
reduce  the  performance  or  damage  the  equipment.  Do  not 
use in an environment containing these chemical substances. 

 
Type 

Substances which must not be present 

Solutions 
 
 

Acetone, benzene, phenol, toluene, trichlen, 
xylene, cresol, thinner, aniline, chloroform, 
chlorobenzene, trichloroethane, ethyl benzene, 
ethanol, methanol, isopropyl alcohol (IPA), 

hexafluoroisopropanol, 

dioxane, tetraohydrohuran, methylene chloride, 
cyclohexane, carbon tetrachloride, 
methyl ketone, ethyl ketone, etc. 

Acids 

Sulfuric acid, nitric acid, hydrochloric acid, acetic 
acid, lactic acid, chromic acid, etc. 

Gases 

Chlorine gas, sulfurous acid gas, hydrogen sulfide, 
bromine,     
ozone, ammonia, etc. 

Oils 

Phosphate  ester  type  hydraulic  fluid,  fuel  oil, 
aqueous cutting oil (alkaline), kerosene, etc. 

Strong 

base 
type 

Lithium  hydroxide,  sodium  hydroxide,  potassium 
hydroxide, calcium hydroxide, etc. 

Others 

Anaerobic adhesive,    anaerobic sealant, etc. 

 

 

 

Operating Environment

 

   

Caution

 

1. Do not operate the product at temperature 

outside the operating temperature range ( fluid 
and ambient temperature) of the specifications.

 

The  membrane  module  (element)  of  this  product  is  resin. 
Operation  at  high  temperature  will  lead  to  damage  of  the 
membrane  module.  Especially when  the  product  is  installed 
after the reciprocation air compressor, be sure to check that 
the  fluid  temperature  is  not  outside  of  the  operating 
condition range.   

 

2. Inlet air temperature should be lower than 

ambient temperature.

 

When  this  product  is  cooled  by  ambient  air,  water  droplets 
accumulate  inside.  It  may  cause  the  decrease  of 
dehumidification  performance  or  flowing  water  droplets  to 
the secondly side of this product. 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

3. 

Maintenance

 

Maintenance 

   

Warning

 

1. Do not remove parts or piping while pressure is 

applied to the product.

 

During maintenance, set air pressure to zero.   

 

   

Caution

 

1. Mount pressure gauge.

 

During a maintenance, mount pressure gauges to both inlet / 
outlet sides for confirming the residual pressure.   

 

2. Standard replacement period.

 

As a guideline the unit should be replaced after 10 years of 
use (10 hours/day). 

 

3. Membrane module cannot be replaced by part.

 

Replace the whole product when replacement is necessary. 

 
 

 
 
 
 
 
 
 
 

 
 