2. Handling precautions

 

 

Design 

   

Caution 

1. Connect the piping in consideration of the 

purge air outlet port position.

 

Purge air is moist. Connect the piping to avoid troubles which 
are corrosion of peripheral devices or malfunction caused by 
purge air. 

 

2. When very clean air is required. 

 

(Supply to the air bearing, semiconductor blow etc.) 
Connect micro mist separator or super mist separator to the 
outlet (in the end) of this product. 

 

3. Time to reach the rated dew point.

 

A certain amount of time is required to achive the rated dew 
point after the air begins to flow.   
Refer to the time below as a guide, to begin operating outlet 
side equipment after the rated dew point is achieved.   

 

Standard dew point -20℃: approx. 10 minutes 

 

4. Ensure that intermittent pressure is not

 

applied 

to the product.

 

(e.g.:  Mount  a  solenoid  valve  on  the  inlet  and  operate  it 
frequently.) 
It  is  possible  to  damage  the  product  if  pressure  is  applied 
intermittently. 

 

 

5. Install a regulator on the outlet side of the

 

product. 

 

If  it  is  installed  on  the  inlet  side,  dehumidification 
performance will be reduced.   
 

6. Do not use the product for applications that 

requires bending and stretching repeatedly.

 

The product might be damaged. 

 

7. With fittings for purge air discharge (Option: P). 

 

The dehumidification capacity decreases in proportion to the 
length  of  the  tube  for  discharging  purge  air.  Use  the 
one-touch  fitting  including  in  the  packaging  and  the  tube 
specified size and keep its length within 5 m. 

 

8. Keep the specified speed for operation.

 

Operation outside of the specified range may cause damage 
to the product. 
 

9. Consider the purge air flow rate. 

 

Find the purge air flow rate from the charts and calculate the 
‘required outlet air flow + purge air flow rate’. The air supply 
capacity must be at least equal to the calculated flow or the 
required outlet air flow rate cannot be obtained.   
 
 
 

 

Mounting and Piping 

   

Caution

 

1. Do not obstruct the purge air discharge ports. 

 

If  purge  air  back  pressure  becomes  too  high  or  purge  air 
stops flowing, dehumidification performance will decrease or 
may become impossible.   

 

2. Make sure to install a mist separator and a

 

micro mist separator or a micro mist separator 
with Pre-filter on the primary side.

 

If the inlet air contains oil or water droplets etc., performance 
will reduce and might be damaged. 

 

3. Large quantities of dust (solid foreign

 

matters) 

or water droplets are present in the supply air.

 

When  there  is  a  large  quantities  of  dusts  (solid  foreign 

matters) in the supply air, follow above No.2, and mount the 
air  filter  or  main  line  filter  in  the  primary  side  of  mist 
separator. When there are large quantities of water droplets, 
follow  above  No.2,  and  mount  the  water  separator  in  the 
primary side of mist separator. 

 

4. Do not use fixtures to the tubes.

 

Using fixtures on tubes may cause damage to the product. 

 

5. Flush the piping before installing. 

 

Before piping, please make sure to remove debris, cutting oil, 
and dusts by performing air blow (flushing).    If foreign matter 
enters the equipment, it may cause malfunction and damage 
of equipment. 

 

6. Do not bend piping less than the minimum

 

bending radius.

 

Minimum bending radius of tubes is 35mm and bending angle 
is 90 degrees or less.    Do not bend the part of 50mm from 
the nut end. Also do not twist. 

 
 
 
 
 
 
 
 
 
 
 
 
 

7. Separate the purge air line and compressed air 

line.

 

Do not blend purge air with compressed air line, condensate 
piping, or exhaust air line of other equipment. If the purge air 
will  not  flow,  it  may  cause  dehumidification  performance 
decline and damage of equipment. 

 

8. Refer to the catalog how to install / remove 

tube.

 

When  you  install  /  remove  tube,  follow  the  Fittings  and 
Tubing Precautions on catalog. Use tubes in the catalog.. 

Do not bend 

50

Minimum bending 
radius 35 

Minimum bending 
radius 35 

50

Do not bend

Nut

Nut