-56-
No.EX
※※
-OMH0025-C
How to increase the output block (power block)
1. Loosen the hexagon socket head cap screws (M3 x 30:2 locations) which are fixing the SI unit.
2. Separate the SI unit to valve manifold.
3. Add and increase the attached tie-rod (2 pcs. per block) to the increased block respectively and pass
through a block by the tie-rod.
4. Fix the mounting brackets (bracket plate) by the attachment hexagon socket head cap screw (M3 x 35:2
locations), paying attention to avoid the gap between each block. (0.6 Nm)
Installation to the DIN rail
When mounting the SI unit and output blocks on the DIN rail, mount the DIN rail mounting bracket on
the bracket plate, and mount it on the DIN rail. Refer to the assembly drawing. At this operation, align
the direction of the tab with that of the mounting bracket on the valve manifold. The manifold is
extended by 21 mm per one station of the output block (power block) and 42.2 mm (SI unit 28.2 mm,
bracket plate 14 mm), so please prepare a DIN rail taking into account the amount extended.