-17-
No.EX
※※
-OMH0025-C
Table: Maximum number of output points when the Power block is used
SI unit model No.
SI unit specification
Max. number of output points
when the Power block is used
EX250-SDN1, -SMJ2, -SPR1, -SCA1A, -SEN1
32 inputs / 32 outputs
24 points
EX260-SDN1, -SDN2, -SMJ1, -SMJ2, -SPR1, -SPR2
EX260-SPR5, -SPR6, -SEN1, -SEN2, -SEC1, -SEC2
EX260-SPN1, -SPN2, -SPL1
32 outputs
24 points
EX260-SDN3, -SDN4, -SMJ3, -SMJ4, -SPR3, -SPR4
EX260-SPR7, -SPR8, -SEN3, -SEN4, -SEC3, -SEC4
EX260-SPN3, -SPN4, -SPL3
16 outputs
16 points
EX126D-SMJ1
16 outputs
16 points
EX250-SAS5, -SAS9
4 inputs / 4 outputs
4 points
EX250-SAS3, -SAS7
8 inputs / 8 outputs
8 points
EX500-Q002, -Q102
Gateway branch system
16 outputs
16 points
EX500-S103
Gateway branch system 2
16/32 outputs
(Selected using built-in
setting switch)
16 outputs
(with setting of 16 outputs)
24 outputs
(with setting of 32 outputs)
: If the Output block is used with the EX250 series, it can be connected to the product with manufacturing lot GV (Aug. 2002) or later.
Terminal block plate (VVQC1000-74A-2) which is shipped after March 2004 can be connected to EX126 for adding the Output block.
These products and assemblies have the body to enable connection with the Output block.