background image

 EX160-TF2Z164EN

 

Page 1 of 2 

 

 

Instruction Manual    

Fieldbus device - SI unit for DeviceNet

®

 

EX160-SDN2

 

 

 
 
 
 
 
 
 
 
 
 
The intended use of this product is to control pneumatic valves and I/O 
while connected to the DeviceNet

®

 protocol. 

1 Safety Instructions 

These safety instructions are intended to prevent hazardous situations 
and/or equipment damage. These instructions indicate the level of 
potential hazard with the labels of “Caution,” “Warning” or “Danger.” 
They are all important notes for safety and must be followed in addition 
to International Standards (ISO/IEC)

 *1)

, and other safety regulations. 

*1)

 ISO 4414: Pneumatic fluid power - General rules relating to systems.  

ISO 4413: Hydraulic fluid power - General rules relating to systems. 
IEC 60204-1: Safety of machinery - Electrical equipment of machines.        
(Part 1: General requirements) 

ISO 10218-1: Manipulating industrial robots -Safety. etc. 

  Refer to product catalogue, Operation Manual and Handling 

Precautions for SMC Products for additional information. 

  Keep this manual in a safe place for future reference. 

 

 

Caution 

Caution indicates a hazard with a low level of risk which, if 

not avoided, could result in minor or moderate injury. 

 

Warning 

Warning indicates a hazard with a medium level of risk 

which, if not avoided, could result in death or serious injury. 

 

Danger 

Danger indicates a hazard with a high level of risk which, if 

not avoided, will result in death or serious injury. 

 

Warning 

 

Always ensure compliance with relevant safety laws and 
standards. 

  All work must be carried out in a safe manner by a qualified person in 

compliance with applicable national regulations. 

 

Caution 

  Provide grounding to assure the noise resistance of the Fieldbus 

system. 
Individual grounding should be provided close to the product using a 
short cable. 

  Refer to the operation manual on the SMC website (URL: 

https://www.smcworld.com

for further Safety Instructions. 

  Special products (-X)  might have specifications different from those 

shown in the specifications section. Contact SMC for specific drawings. 

 

 

 

 

 

 

2 Specifications 

2.1  General specifications 

Item 

Specifications 

Ambient temperature 

-10 to +50 

o

Ambient humidity 

35 to 85%RH (No condensation) 

Storage temperature  

-20 to +60 

o

Withstand voltage 

1000 VAC applied for 1 minute  

(between FG and external terminal) 

Insulation resistance 

10 M

Ω

 or more (500 VDC, between FG and 

external terminal) 

Operating atmosphere 

No corrosive gas 

Enclosure 

IP20 

Weight 

320 g 

 

2.2  Electrical specifications 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.3  Communication specifications 

Item 

Specifications 

Protocol 

DeviceNet

®

 

Volume1 (Edition 3.5) 

Volume 3 (Edition 1.5) 

Slave type 

Group 2 Only Server 

Device type 

1Bh (Pneumatic Valve(s)) 

Data rate 

125 kbps / 250 kbps / 500 kbps 

Node address 
setting range 

00h to 3Fh (0 to 63) 

Product code 

86h (134) 

Vendor ID 

07h (SMC Corporation) 

Applicable 
message 

Duplicate MAC ID Check Message 

Unconnected Explicit Message 

Explicit Message 

Poll I/O Message  

(predefined M/S connection set) 

Configuration file 

EDS file 

EDS file (Please download from SMC) 

Occupied area 
(Number of 
Inputs/Outputs) 

16 inputs / 16 outputs * 

* Although EX160-SDN2 does not have any input channels. 

 

 

 

 

 

 

 

3 Name and function of parts 

EX160-SDN2 

 

 

No. 

Part 

Description 

Mounting hole 

Holes to mount the SI unit (4 positions). 

DeviceNet

®

 

connector 

Connector for DeviceNet

®

 (M12 5-pin plug, 

A-coded). 

LED display 

LED’s to indicate Bus status and SI unit 
status. 

Interlock 
connector 

Connector for external interlock circuit 
(44-pin D-sub plug connector).

 

Switches 

Switches for setting of node address and 
operating mode. 

 
 
 
 
 

4 Installation 

4.1  Mounting 

Warning 

  Do not install the product unless the safety instructions have been read 

and understood. 

  Applicable valve series: VQ1000. 

Caution 

  Be sure to turn OFF the power. 

  Mount the SI unit using the 4 mounting holes in  the base using  M4 

screws. Tightening torque must be 1.3 to 1.7 N•m. 

 

4.2  Environment 

Warning 

  Do not use in an environment where corrosive gases, chemicals, salt 

water or steam are present. 

  Do not use in an explosive atmosphere. 

  Do not expose to direct sunlight. Use a suitable protective cover. 

  Do not install in a location subject to vibration or impact in excess of 

the product’s specifications.  

  Do not mount in a location exposed to radiant heat that would result in 

temperatures in excess of the product’s specifications. 

5 Wiring 

5.1  Communication Connector 

  Select the appropriate cable  (SMC part number PCA-1557633 or 

EX500-AC050-DN) to mate with the connector on the SI unit. 

  The bus connector layout for DeviceNet

®

 is as follows. 

Connector: M12 5-pin plug, A-coded 

No. 

Signal 

Description 

DRAIN 

Drain / Shield 

V+ 

Power  for DeviceNet

®

 

V- 

Power supply - for DeviceNet

®

 

CAN_H 

CAN_H bus line (dominant high) 

CAN_L 

CAN_L bus line (dominant low) 

 

5.2  Bus Terminator 

  A bus termination resistor is required at both ends of the DeviceNet

®

 

trunk line. 
The specification of the terminating resistor is 121 

Ω 

±

1%, 1/4 W. 

 

5.3  Interlock connector 

  The interlock connector pin allocation is as shown below. 

Interlock connector: 44-pin D-sub plug connector 

 

 

 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

  Pin numbers 33 to 42 are not used (reserved). 

  The power supply for solenoid valves should be supplied using the 

connector pins given above. 

  The power supply for the SI unit operation is isolated. Be sure to supply 

power separately using the M12 5-pin communication connector. 
Either single-source power supplies or two different power supplies 
can be used. 

 

5.4  Ground Connection 

  Connect the product to ground using a mounting hole screw. 

Individual grounding should be provided close to the product. 
Resistance to ground should be 100 ohms or less. 
Tightening torque for the M4 screw is 1.3 to 1.7 N•m. 

 
 
 
 
 
 
 
 

ORIGINAL INSTRUCTIONS 

 

 

 

Item 

Specifications 

Network section 

Power supply  
voltage range / 
Current 
consumption 

Controller 
power supply

 

11 to 25 VDC 

Current 
consumption 

0.1 A or less (at 24 VDC) 

Network Isolation 

photocoupler 

Solenoid section 

Power supply  
voltage range / 
Current 
consumption 

Solenoid valve 
power supply 

22.8 to 26.4 VDC 

Current 
consumption 

1.4 A or less (according to 

solenoid valve specification). 

Connected load 

24 VDC and 2.1 W or less 

solenoid valve with surge voltage 

suppressor 

(manufactured by SMC). 

Driver circuit 

Mechanical relay (PNP output) 

Solenoid channels 

16 

Interlock channels 

16 

Interlock function 

Enable / Force 

Output type 

PNP (negative common) / source 

 

Description 

Pin assignment 

Valve 

station 

Solenoid 

No. 

Output 

channel 

Enable 

Force 

Common 

(0 V) 

1A 

13 

28 

 

1B 

12 

27 

 

2A 

11 

26 

 

2B 

10 

25 

 

3A 

24 

 

3B 

23 

 

4A 

22 

 

4B 

21 

 

5A 

20 

 

5B 

19 

 

6A 

10 

31 

32 

 

6B 

11 

18 

 

7A 

12 

15 

30 

 

7B 

13 

17 

 

8A 

14 

14 

29 

 

8B 

15 

16 

 

 

 

 

 

 

43, 44 

 

Reviews: