Document Revision:   1.E 

Web Configurator 

Template Revision:  3 

ProtoCessor FPC-ED4 

Start-up Guide 

For Interfacing Electro Industries Products: 

Meter

To Building Automation Systems: 

LonWorks and SMC Cloud 

APPLICABILITY & EFFECTIVITY

 

Explains ProtoCessor hardware and how to install it. 

The instructions are effective for the above as of July 2019. 

07/10/2019     BI806

Summary of Contents for Electro Industries ProtoCessor

Page 1: ...4 Start up Guide For Interfacing Electro Industries Products Meter To Building Automation Systems LonWorks and SMC Cloud APPLICABILITY EFFECTIVITY Explains ProtoCessor hardware and how to install it T...

Page 2: ...toCessor product Sierra Monitor Corporation does not provide direct support If Electro Industries needs to escalate the concern they will contact Sierra Monitor Corporation for assistance Support Cont...

Page 3: ...LonWorks port to the field protocol cabling Section 4 3 4 Connect a PC to the ProtoCessor via Ethernet cable Section 5 1 5 Ethernet Network Use a browser to access the ProtoCessor FS GUI to change th...

Page 4: ...etting IP Address for the Field Network 13 6 Commissioning ProtoCEssor on a LonWorks Network 15 6 1 Commissioning ProtoCessor FPC ED4 on a LonWorks Network 15 6 1 1 Instructions to Upload XIF File fro...

Page 5: ...LonWorks Terminal Connector 10 Figure 8 Ethernet Port Location 11 Figure 9 FS GUI Landing Page 13 Figure 10 Changing IP Address via FS GUI 14 Figure 11 LonWorks Service Pin Location 15 Figure 12 Samp...

Page 6: ...tors and end users LonMark International has developed extensive product certification standards and tests to provide the integrator and user with confidence that products from multiple manufacturers...

Page 7: ...th Sierra Monitor s SMC Cloud The SMC Cloud allows technicians the OEM s support team and Sierra Monitor s support team to remotely connect to the ProtoCessor The SMC Cloud provides the following capa...

Page 8: ...al number of registers presented the device s attached to the ProtoCessor cannot exceed Part number Total Registers FPC ED4 1564 1 500 Figure 2 Supported Point Count Capacity Devices Registers Per Dev...

Page 9: ...Electro Industries ProtoCessor Start up Guide Page 9 of 32 4 INTERFACING PROTOCESSOR TO DEVICES 4 1 ProtoCessor Mounted onto Board Example Figure 5 Mounted ProtoCessor Example 07 10 2019 BI806...

Page 10: ...nnection Ports 4 3 Wiring Field Port to LonWorks Network Wire the LonWorks device network to the ProtoCessor LonWorks Terminal o Use approved cable per the FT 10 installation guidelines LonWorks has n...

Page 11: ...92 168 1 24 Subnet Mask is 255 255 255 0 If the PC and ProtoCessor are on different IP networks assign a static IP Address to the PC on the 192 168 1 xxx network For Windows 10 Find the search field i...

Page 12: ...green then the IP Address doesn t need to be changed the ProtoCessor is already on the same subnet Skip the rest of the section Select Network Settings in the Configure Device window Modify the IP Ad...

Page 13: ...e ProtoCessor the default Ethernet address is 192 168 1 24 o If using the FieldServer Toolbox Section 5 1 2 click the Connect button NOTE If the IP Address of the ProtoCessor has been changed the IP A...

Page 14: ...at managed switch router Click the System Restart button at the bottom of the page to apply changes and restart the ProtoCessor Unplug Ethernet cable from PC and connect it to the network switch or ro...

Page 15: ...ween the PC and ProtoCessor The default IP Address for the ProtoCessor is 192 168 1 24 Subnet Mask is 255 255 255 0 If the PC and ProtoCessor are on different IP networks assign a static IP Address to...

Page 16: ...IP Address of ProtoCessor fserver xif o Example 192 168 1 24 fserver xif If the web browser prompts to save the file save the file onto the PC If the web browser displays the xif file as a web page s...

Page 17: ...xecutable file and complete the installation Connect a standard Cat 5 Ethernet cable between the user s PC and ProtoCessor Double click on the FS Toolbox Utility and click Discover Now on the splash p...

Page 18: ...he ProtoCessor into the web browser or use the FieldServer Toolbox to connect to the ProtoCessor Click on Diagnostics Button then click on view and then on connections If there are any errors showing...

Page 19: ...bservations of LEDs on ProtoCessor Appendix A 4 o Check baud rate parity data bits stop bits o Check device address o Verify wiring o Verify device is connected to the same subnet as the ProtoCessor F...

Page 20: ...after power up It will turn off after 5 seconds A steady red light will indicate there is a system error on ProtoCessor If this occurs immediately report the related system error shown in the error s...

Page 21: ...pture utilities are embedded in the FS GUI web interface Starting a diagnostic capture takes a snapshot of the loaded configuration files and a log of all the communications over a specified period of...

Page 22: ...Start up Guide Page 22 of 32 Step 1 Take a Log o Click on the diagnose icon of the desired device o Ensure Full Diagnostic is selected this is the default NOTE If desired the default capture period c...

Page 23: ...period to finish then the Diagnostic Test Complete window will appear Step 2 Send Log o Once the Diagnostic test is complete a zip file is saved on the PC o Choose Open to launch explorer and have it...

Page 24: ...ic Capture is complete email it to technical support The Diagnostic Capture will accelerate diagnosis of the problem Open the FieldServer FS GUI page Click on Diagnostics in the Navigation panel Go to...

Page 25: ...address bar o Default IP Address is 192 168 1 24 o Use the FS Toolbox utility if the IP Address is unknown Appendix A 1 3 Click on the Diagnostics Debugging button 4 In the Navigation Tree on the lef...

Page 26: ...restricted access to the ProtoCessor The User account can view any ProtoCessor information but cannot make any changes or restart the ProtoCessor The password needs to be a minimum of eight characters...

Page 27: ...Stgs SNVT_count_f Differential Deg_F nvi nvoDifferentialF SNVT_count_f Troubleshooting Stage Code nvi nvoTrblshtStgCde SNVT_count_f 0 to 10VDC No or Yes nvi nvo0to10VDC SNVT_count_f Stage Seq Minutes...

Page 28: ...Electro Industries ProtoCessor Start up Guide Page 28 of 32 Differential Deg_C nvi nvoDifferentialC SNVT_count_f 07 10 2019 BI806...

Page 29: ...r Temperature F ST Supply Temperature F Current Stage Code Number of stages currently ON Mode 1 Setpoint 2 TS A Reset 3 0 10 VDC Input 4 Troubleshooting Fault Counts 0 9999 1 Auto HL 2 Bender 3 LWCO 4...

Page 30: ...roubleshooting Stage Code 0 15 Default 0 0 10VDC YES NO Default NO Stage Sequence Minutes 0 99 minutes Default 1 Boiler Type 1 Single Default 2 Lead 3 Lag Lag Boiler Delay 0 999 minutes Default 15 For...

Page 31: ...nge without notice Figure 19 Specifications Appendix D 1 1 Compliance with UL Regulations For UL compliance the following instructions must be met when operating ProtoCessor The units shall be powered...

Page 32: ...n or on which original identification marks have been removed or altered This Limited Warranty also will not apply to interconnecting cables or wires consumables or to any damage resulting from batter...