background image

How to Mount and Move the Auto Switch

D-M9K 

Mounting Bracket

 

Direct Mounting Type

D-Y7K 

Mounting Bracket

 

Direct Mounting Type

<Applicable auto switch>

Solid state ······

D-M9K

<Applicable auto switch>

Solid state ······

D-Y7K

How to Mount and Move the Auto Switch

How to Mount and Move the Auto Switch (1)

How to Mount and Move the Auto Switch (2)

Hexagon socket 
head cap screw
(M2.5 x 12L)

Auto switch

Note)  When tightening an auto switch mounting screw, use a watchmaker’s 

screwdriver with a grip diameter of 5 to 6 mm. Also, tighten with a 
torque of about 0.05 to 0.1 N·m 
As a guide, it should be turned about 90° past the point at which 
tightening can be felt.

Note)  When tightening an auto switch mounting screw, use a watchmaker’s 

screwdriver with a grip diameter of 5 to 6 mm. Also, tighten with a 
torque of about 0.05 to 0.1 N·m 
As a guide, it should be turned about 90° past the point at which 
tightening can be felt.

Note)  The tightening torque for a hexagon socket head cap screw 

(M2.5 x 12L) is 0.1 to 0.2 N·m. 

1.  Insert the auto switch into the mounting groove and set it at the 

auto switch mounting position.

2.  After reconfirming the detecting position, tighten the mounting 

screw to secure the auto switch.

3.  Modification of the detecting position should be made in the 

condition of 1.

1.  After picking up a switch spacer between your fi ngers, push it in 

the cylinder tube groove.

2.  Confi rm that it is set in the correct mounting orientation.

Correct

Incorrect

3.  Insert the auto switch into the mounting groove and set it at the 

auto switch mounting position.

4.  After reconfirming the detecting position, tighten the mounting 

screw to secure the auto switch.

Auto switch 
mounting screw

Auto switch

Switch spacer
BMP1-032

Auto switch 
mounting screw

Auto switch

Applicable Actuators

Air Grippers

Description

Series

Bore size 

Parallel style

MHZ2

16 to 40

Parallel style

MHZJ2

16 to 25

Parallel style

MHS2 

(2 fi ngers)

20, 25

Parallel style

MHS3

 (3 fi ngers)

20, 25

Parallel style

MHS4

 (4 fi ngers)

20, 25

Air Cylinders

Description

Series

Bore size

Compact cylinder

CQ2-Z

12 to 200

Compact cylinder guide rod type

CQM

12 to 100

3 position cylinder

RZQ

32 to 63

Rotary clamp cylinder

MK-Z

12 to 63

Compact guide cylinder

MGP-Z

12 to 100

Applicable Actuators

Air Grippers

Description

Series

Bore size 

Parallel style

MHZ2

10 to 40

Parallel style

MHZL2

10 to 25

Wide type

MHL2

10 to 40

Parallel style

MHS2 

(2 fi ngers)

32 to 63

Parallel style

MHS3

 (3 fi ngers)

/MHS(L)3

32 to 63

Parallel style

MHS4

 (4 fi ngers)

32 to 63

Angular style

MHC2

10 to 25

180° Angular style

MHW2

20 to 50

Air Cylinders

Description

Series

Bore size 

Non-rotating double power cylinder

MGZ

40 to 63

Compact guide cylinder

MGP

12 to 100

Auto Switch Mounting Bracket/Part No.

(Switch spacer and auto switch mounting bracket)

Cylinder series

Bore size 

40

50

63

MGZ

BMP1-032

BMP1-032

BMP1-032

5

Series 

D-M9K/D-

7K/D-R

Summary of Contents for D 7K Series

Page 1: ...it is ON With one switch various sized work pieces can be detected by the difference of 0 5 mm or more From 0 5 mm to detectable width dependant on applied actuator 0 5 mm Minimum adjustment width to detect OUT2 Trimmer OUT1 Trimmer One auto switch allows work pieces to be distinguished easily Direct mounting Round groove type newly added GreenlightisON RedlightisON GreenlightisON OrangelightisON ...

Page 2: ...tor IP P6 67 Sensor unit O Only y o one ne ne a a aut ut uto o o sw sw swit it itch ch ch c c can an an d d det et etec ec ect t t th th the e e ex ex exte te tend nd nded ed ed an nd d d re etr trac acte te ted d d en en end d d po po posi si siti ti tion on ons s s Th h his s s sw witch can be used when two auto switches ca a an nn not be mounted due to short stroke Sensor Unit Amplifier Unit Se...

Page 3: ...ent 80 mA or less 1 output Internal voltage drop 1 5 V or less Leakage current 100 μA or less 1 output Response time 1 ms or less Indicator lamp READY Red lights ON when the piston position detected with sensor unit OUT1 Green lights ON when turned ON OUT2 Orange lights ON when turned ON Electrical entry Connection to sensor e con connector Powersupply outputcable Grommet Impact resistance 98 m s2...

Page 4: ...ore size 10 12 16 20 25 32 40 50 63 80 100 Parallel style MHZ2 3 0 5 0 7 0 7 0 8 0 8 5 Parallel style MHZL2 6 0 7 0 10 0 11 0 Wide type MHL2 7 0 8 0 8 5 10 5 11 0 12 5 Parallel style MHS2 2 fingers 6 5 7 0 7 5 8 5 Parallel style MHS3 3 fingers MHS L 3 6 5 7 0 7 5 8 0 Parallel style MHS4 4 fingers 6 5 7 0 7 5 8 5 Angular style MHC2 30 to 10 30 to 10 30 to 10 22 5 to 10 180 Angular style MHW2 88 to ...

Page 5: ...e position 15 4 7 8 ø3 2 ø3 5 3000 23 4 6 11 1 8 5 Most sensitive position 6 2 3 2 8 6 12 7 7 2 6 12 5 56 5 3000 ø3 5 DIN rail 35 mm width Supplied by users 2 x ø3 5 21 1 6 30 Connector for sensor e con 5 46 ø2 0 Mounting thread M2 5 x 12L Hexagon socket head cap screw Dimensions Sensor Unit D M9K D F7K D Y7K Amplifier Unit D R첸K 4 Trimmer Auto Switch Series D M9K D 첸7K D R첸K ...

Page 6: ...rs push it in the cylinder tube groove 2 Confirm that it is set in the correct mounting orientation Correct Incorrect 3 Insert the auto switch into the mounting groove and set it at the auto switch mounting position 4 After reconfirming the detecting position tighten the mounting screw to secure the auto switch Auto switch mounting screw Auto switch Switch spacer BMP1 032 Auto switch mounting scre...

Page 7: ...tch Tightening torque of M3 screw should be 0 5 to 0 7 N m 5 Modification of the detecting position should be made in the condition of 3 Auto Switch Mounting Bracket Part No Including Nut Screw Spacer Cylinder series Bore size 12 16 20 25 32 40 50 63 80 100 125 140 160 CQ2 BQ 1 BQ 1 BQ 1 BQ 1 BQ 2 BQ 2 BQ 2 BQ 2 BQ 2 BQ 2 BQ 2 BQ 2 BQ 2 MU BMU1 025 BMU1 025 BMU1 025 BMU1 025 BMU1 025 MK MK2 BQ 1 B...

Page 8: ...tecting position carry out in the state of 2 To protect auto switches ensure that main body of an auto switch should be embedded into auto switch mounting groove with a depth of 15 mm or more Auto Switch Mounting Bracket Part No Including Bracket Set Screw Cylinder series Bore size 40 50 63 80 100 CA2 BA4 040 BA4 040 BA4 063 BA4 080 BA4 080 Auto switch mounting screw Auto switch Auto switch mounti...

Page 9: ... occur shut off the power supply remove the cause of this excess current flow and switch on the power again Take special care to avoid reverse wiring between the power supply line brown and the output line black white Wiring Caution 4 Avoid incorrect wiring If the connections are reversed power supply line and power supply line the trimmer auto switches will be protected by a protection circuit Ho...

Page 10: ......

Page 11: ......

Page 12: ...equipment in conjunction with atomic energy railways air navigation space shipping vehicles military medical treatment combustion and recreation or equipment in contact with food and beverages emergency stop circuits clutch and brake circuits in press applications safety equipment or other applications unsuitable for the standard specifications described in the product catalogue 3 An application w...

Reviews: