background image

rkpiece

Small workpiece

La

rge workpiece

Medium workpiece

No wor

Small workpiece

Square groove

Round groove

Rail groove

Medium workpiece

Large workpiece

Adjustable by trimmer

Adjustable by trimmer

OUT2 Detecting range

Output ON = Orange light is ON.

OUT1 Detecting range

Output ON = Green light is ON.

Operating range of sensor (Red light of the sensor unit is ON.)

With one switch, various sized work pieces 

can be detected by the difference of 

0.5 mm or more.

 From 0.5 mm to detectable width 

dependant on applied 

actuator.

0.5

 mm

Minimum adjustment

width to detect

OUT2 Trimmer

OUT1 Trimmer

One auto switch allows work pieces to be distinguished easily.

Direct mounting (Round groove) 
type newly added

Green 

light is ON.

Red 

light is ON.

Green 

light is ON.

Orange 

light is ON.

Orange 

light is ON.

Red 

light is ON.

Red 

light is ON.

OUT1

 and 

OUT2

 are 

adjustable separately.

RoHS

Trimmer Auto Switch

CAT.EUS20-180C-UK

Series 

D-M9K/D-

7K/D-R

K

Summary of Contents for D 7K Series

Page 1: ...it is ON With one switch various sized work pieces can be detected by the difference of 0 5 mm or more From 0 5 mm to detectable width dependant on applied actuator 0 5 mm Minimum adjustment width to detect OUT2 Trimmer OUT1 Trimmer One auto switch allows work pieces to be distinguished easily Direct mounting Round groove type newly added GreenlightisON RedlightisON GreenlightisON OrangelightisON ...

Page 2: ...tor IP P6 67 Sensor unit O Only y o one ne ne a a aut ut uto o o sw sw swit it itch ch ch c c can an an d d det et etec ec ect t t th th the e e ex ex exte te tend nd nded ed ed an nd d d re etr trac acte te ted d d en en end d d po po posi si siti ti tion on ons s s Th h his s s sw witch can be used when two auto switches ca a an nn not be mounted due to short stroke Sensor Unit Amplifier Unit Se...

Page 3: ...ent 80 mA or less 1 output Internal voltage drop 1 5 V or less Leakage current 100 μA or less 1 output Response time 1 ms or less Indicator lamp READY Red lights ON when the piston position detected with sensor unit OUT1 Green lights ON when turned ON OUT2 Orange lights ON when turned ON Electrical entry Connection to sensor e con connector Powersupply outputcable Grommet Impact resistance 98 m s2...

Page 4: ...ore size 10 12 16 20 25 32 40 50 63 80 100 Parallel style MHZ2 3 0 5 0 7 0 7 0 8 0 8 5 Parallel style MHZL2 6 0 7 0 10 0 11 0 Wide type MHL2 7 0 8 0 8 5 10 5 11 0 12 5 Parallel style MHS2 2 fingers 6 5 7 0 7 5 8 5 Parallel style MHS3 3 fingers MHS L 3 6 5 7 0 7 5 8 0 Parallel style MHS4 4 fingers 6 5 7 0 7 5 8 5 Angular style MHC2 30 to 10 30 to 10 30 to 10 22 5 to 10 180 Angular style MHW2 88 to ...

Page 5: ...e position 15 4 7 8 ø3 2 ø3 5 3000 23 4 6 11 1 8 5 Most sensitive position 6 2 3 2 8 6 12 7 7 2 6 12 5 56 5 3000 ø3 5 DIN rail 35 mm width Supplied by users 2 x ø3 5 21 1 6 30 Connector for sensor e con 5 46 ø2 0 Mounting thread M2 5 x 12L Hexagon socket head cap screw Dimensions Sensor Unit D M9K D F7K D Y7K Amplifier Unit D R첸K 4 Trimmer Auto Switch Series D M9K D 첸7K D R첸K ...

Page 6: ...rs push it in the cylinder tube groove 2 Confirm that it is set in the correct mounting orientation Correct Incorrect 3 Insert the auto switch into the mounting groove and set it at the auto switch mounting position 4 After reconfirming the detecting position tighten the mounting screw to secure the auto switch Auto switch mounting screw Auto switch Switch spacer BMP1 032 Auto switch mounting scre...

Page 7: ...tch Tightening torque of M3 screw should be 0 5 to 0 7 N m 5 Modification of the detecting position should be made in the condition of 3 Auto Switch Mounting Bracket Part No Including Nut Screw Spacer Cylinder series Bore size 12 16 20 25 32 40 50 63 80 100 125 140 160 CQ2 BQ 1 BQ 1 BQ 1 BQ 1 BQ 2 BQ 2 BQ 2 BQ 2 BQ 2 BQ 2 BQ 2 BQ 2 BQ 2 MU BMU1 025 BMU1 025 BMU1 025 BMU1 025 BMU1 025 MK MK2 BQ 1 B...

Page 8: ...tecting position carry out in the state of 2 To protect auto switches ensure that main body of an auto switch should be embedded into auto switch mounting groove with a depth of 15 mm or more Auto Switch Mounting Bracket Part No Including Bracket Set Screw Cylinder series Bore size 40 50 63 80 100 CA2 BA4 040 BA4 040 BA4 063 BA4 080 BA4 080 Auto switch mounting screw Auto switch Auto switch mounti...

Page 9: ... occur shut off the power supply remove the cause of this excess current flow and switch on the power again Take special care to avoid reverse wiring between the power supply line brown and the output line black white Wiring Caution 4 Avoid incorrect wiring If the connections are reversed power supply line and power supply line the trimmer auto switches will be protected by a protection circuit Ho...

Page 10: ......

Page 11: ......

Page 12: ...equipment in conjunction with atomic energy railways air navigation space shipping vehicles military medical treatment combustion and recreation or equipment in contact with food and beverages emergency stop circuits clutch and brake circuits in press applications safety equipment or other applications unsuitable for the standard specifications described in the product catalogue 3 An application w...