100 Mbps Fast Ethernet Collision Domain
SMC 3 - 2 Rule for Class
II
Repeaters
SMC 2 - 1 Rule for Class I and Class II Repeaters
Maximum 100BASE-T Network Diameter
Maximum 100BASE-T Cable Distance
I
NSTALLATION
3-10
Between any two PCs or other stations in the same 100BASE-T
collision domain, there may be:
• up to 3 link segments and
• up to 2 Class II repeaters (hubs)
Between any two PCs or other stations in the same 100BASE-T
collision domain, there may be:
• up to 2 link segments and
• only 1 Class I or Class II repeater (hub)
Repeater Type
Twisted Pair
Twisted Pair/Fiber
and Number
100BASE-TX/T4 100BASE-T4/FX
100BASE-TX/FX
1 Class I
200 m (656 ft.)
231 m (757.7 ft.)
260.8 m (855.4ft.)
1 Class II
200 m (656 ft.)
304 m (997.1 ft.)
308.8 m (1012.9 ft.)
2 Class II
205 m (672.4 ft.)
236.3 m (775.1 ft.) 216.2 m (709.1 ft
.)
Cable Type
Connecting
Max. Distance
T
wisted Pair
Any two devices
100 m (328 ft.)
Fiber
Switch to Switch, Server or PC
Half duplex
412 m (1,351.4 ft.)
Full duplex
2 km (1.24 mi.)
MII
Any two devices
0.5 m (1.6 ft.)
Summary of Contents for 6608T-INT
Page 37: ......
Page 51: ......
Page 95: ......
Page 107: ......