Model 5100-XX-IT Toxic Gas Sensor Module

 

Page:  32 

APPENDIX C: LIMITED WARRANTY 

SIERRA MONITOR CORPORATION warrants its products to be free from defects in workmanship or material 
under normal use and service for two years after date of shipment.  SMC will repair or replace without charge 
any equipment found to be defective during the warranty period.  Final determination of the nature and 
responsibility for defective or damaged equipment will be made by SMC personnel. 

All warranties hereunder are contingent upon proper use in the application for which the product was intended 
and do not cover products which have been modified or repaired without SMC approval or which have been 
subjected to accident, improper maintenance, installation or application, or on which original  identification 
marks have been removed or altered.  This Limited Warranty also will not apply to interconnecting cables or 
wires, consumables (ie. calibration gases, batteries, sensors), nor to any damage resulting from battery 
leakage. 

In all cases SMC’s responsibility and liability under this warranty shall be limited to the cost of the equipment.  
The purchaser must obtain shipping instructions for the prepaid return of any item under this warranty 
provision and compliance with such instruction shall be a condition of this warranty. 

Except for the express warranty stated above, SMC disclaims all warranties with regard to the products sold 
hereunder including all implied warranties of merchantability and fitness and the express warranties stated 
herein are in lieu of all obligations or liabilities on the part of SMC for damages including, but not limited to, 
consequential damages arising out of/or in connection with the use or performance of the product. 

 

Summary of Contents for 5100 IT Series

Page 1: ...SOR MODULE Version 2 0 APPLICABILITY EFFECTIVITY Effective for all Model 5100 XX IT and 5100 XX IT SS Modules manufactured after March 1 2008 including 5100 03 IT 5100 04 IT 5100 05 IT 5100 06 IT Inst...

Page 2: ...Contents THIS PAGE INTENTIONALLY LEFT BLANK...

Page 3: ...7 3 1 SENSOR MODULE LOCATIONS 7 3 2 WIRING 7 3 2 1 ANALOG 4 20 mA OPERATION 7 3 2 2 MODBUS OPERATION USING RS 485 CONNECTION 7 3 2 3 SENTRY OPERATION USING SMC SENTRY CONNECTION 7 3 2 4 GENERAL 7 3 3...

Page 4: ...MODULE DOES NOT RESPOND TO GAS 28 6 5 4 IF THE MODULE DISPLAYS STARTING FOR MORE THAN 1 HOUR 28 7 APPENDICES 29 APPENDIX A SPECIFICATIONS 29 APPENDIX B MODEL NUMBERS PARTS LIST 31 APPENDIX C LIMITED W...

Page 5: ...configured prior to shipment Options which can be re configured by the installer or field technician are fully described in this manual 1 3 THEORY OF OPERATION Electrochemical sensors are fuel cell li...

Page 6: ...connection to standard analog controllers or PLCs The 5100 XX IT 4 20 mA connection can be wired as a Type 3 3 wire or Type 4 4 wire circuit as described by ANSI ISA 50 00 01 1975 Standard see figure...

Page 7: ...Page 3 Figure 1 1 Model 5100 05 IT Toxic Gas Sensor Module Aluminum Enclosures Dimensions Figure 1 2 Model 5100 05 IT Toxic Gas Sensor Module 316 Stainless Steel Enclosures Dimensions...

Page 8: ...ssembly is threaded to allow connection of a rain shield or calibration gas delivery fitting 1 5 INTERCONNECT WIRING Not supplied with the sensor module but necessary to the installation and operation...

Page 9: ...a sintered metal cover If this cover becomes clogged the response of the sensor will be reduced Protect the sensor from contamination by careful placement or by use of rain and dust shields Sensor mo...

Page 10: ...Page 6 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 11: ...of 18 AWG 2 conductor for DC power connection No shield required In addition use a minimum of 24 AWG low capacitance shielded data cable for RS 485 half duplex communication The installation may be p...

Page 12: ...When housing earth grounding is required for the installation a grounding lug is located in the base of the enclosure Install the earth ground wire under the green lug When installing the enclosure b...

Page 13: ...Power 5 S Signal 6 G Ground P4 Connections are only available when the optional Relays are included P4 PCB Label Function 1 N C Low Alarm Relay NC 2 COM Low Alarm Relay COM 3 LO ALM N O Low Alarm Rela...

Page 14: ...3 B Sensor 11 4 Sensor 4 C Sensor 12 5 Sensor 5 D Sensor 13 6 Sensor 6 E Sensor 14 7 Sensor 7 F Sensor 15 8 Sensor 8 0 Software Menu Table 3 2 Sensor Module Address Switch Positions NOTE For Sentry ap...

Page 15: ...Page 11 Figure 3 2 Interface Board Connectors Figure 3 3 RS 485 120 ohm termination not selected BIAS shunted for 100K ohm bias...

Page 16: ...Page 12 Figure 3 4 4 20mA Circuit Types...

Page 17: ...Page 13 Figure 3 5 4 20mA Circuit Type Connections for 5100 XX IT...

Page 18: ...Page 14 For end of line refer to Figure 3 3 Figure 3 6 Wiring Connections for Modbus and Sentry Interface...

Page 19: ...Page 15 5100 05 IT REMOTE ALARM RESET SUPERVISED SWITCH IN SWITCH IN GND IN IN OUT SWITCH 4 20 4 20 P1 4 7K OHM CUSTOMER SUPPLIED Figure 3 7 Wiring Connections for Remote Alarm Reset...

Page 20: ...Page 16 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 21: ...procedures and alarms acknowledge 4 2 HUMAN MACHINE INTERFACE The module menu system is operated by means of directing the magnet stick toward each of four independent hall effect magnetic switches E...

Page 22: ...de Function Alarm Reset XXXPPM Default Display RESET Alarm Reset Banner Press E to reset alarm Mode ALMRSET Mode Function Alarm Reset XXXPPM Normal condition default display STARTING Third screen at s...

Page 23: ...the high end of the range desired 4 20mA Once the Set up menu is selected press key three times and press E to activate the 4 20mA Set up menu Use the or keys to select Calib or CalibOut menu and pre...

Page 24: ...Function 4 20 mA Adjust Page 21 Down RS 485 S P Function RS 485 Sentry Output Adjust Page 21 High Alarm Set Point Adjustment Example Enter H Alarm S P Function High Alarm Adjust A Enter HASP 60 High...

Page 25: ...select 4 mA or 20mA Enter 4mA Selects 4 mA Enter ACK Momentary Acknowledge of new Set Point Mode Calib S P Function Calib Adjust Down CalibOut S P Function Output during Calibration Adjust Enter Track...

Page 26: ...enu operation is described in Table 4 4 Function Display Description Reference M E S T M E S T M E S T M E S T M E S T M E S T Table 4 4 Maintenance Menu Enter CCC001 Module Custom Configuration Contr...

Page 27: ...Model 5100 XX IT Toxic Gas Sensor Module Page 23 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 28: ...tion procedure can then be restarted Calibration must be performed only when the area is known to be clear of the applicable toxic gas If necessary use a portable instrument to confirm that there is n...

Page 29: ...bration gas Enter 10PPM SP Banner Select span enter E when done Up 25PPM SP Operation Change Span Gas Value to 25PPM Sub A WAIT 300 Operation Five minute time out before sensor is returned to service...

Page 30: ...E CONFIGURATION The gas sensor module is comprised of the following sub assemblies Figure 6 1 5100 XX IT Gas Sensor Module SPL21810 Aluminum Enclosure SPL32178 316SS Enclosure SPL21825 Transmitter Ass...

Page 31: ...the sensor assembly housing can be replaced without replacement of the housing The gas sensor needs replacement when The CAL FAIL message appears after calibration The sensor output signal is noisy ca...

Page 32: ...on if a fault occurs 6 5 3 IF MODULE DOES NOT RESPOND TO GAS 1 Repeat calibration procedure 2 Remove the gas and wait for the timer to completely count down 3 Apply 50 PPM and verify that the sensor s...

Page 33: ...nal Analog 4 20 mA Trouble 0 mA Calibration 1 5 mA Signal Output Sentry bus Serial RS 485 Modbus RTU Input Remote Alarm Reset Normally open digital input supervised or non supervised Electrical Data P...

Page 34: ...Flow Control None Memory map Appendix E Warranty Limited Warranty 2 years Specifications subject to change without notice Ordering Information 5100 XX IT YY ZZ 5100 Series 03 O2 04 CO IT Series 05 H2S...

Page 35: ...nder H2S in N2 25 PPM Type A 57 litres 1260 06 Gas Cylinder Cl2 5 PPM Type C 104 litres 1260 13 Gas Cylinder CO 1000 PPM Type A 105 liters 5360 00 Calibrator Head Standard 1256 01 Regulator Type A Cal...

Page 36: ...original identification marks have been removed or altered This Limited Warranty also will not apply to interconnecting cables or wires consumables ie calibration gases batteries sensors nor to any da...

Page 37: ...Model 5100 XX IT Toxic Gas Sensor Module Page 33 APPENDIX D REMOTE SENSOR DISPLAY DRAWING 5394 52...

Page 38: ...High Alarm Value High alarm set point used for activating High Alarms 40007 Reserved 40008 Reserved 40009 Reserved 40010 Reserved 40011 Trouble Bits 0 for no trouble 40012 Trouble 1 for any trouble 0...