Pass Count Fail Count
A.
I/O Register
B.
100Mbps Loopback
C.
10Mbps Loopback
D.
Cable Connection
<Cable Connection> test shows you that the connection link might fail because either the cable is not
connected or the cable link fails.
For the <Run Diagnostics on Network> test, it is necessary to connect your computer with a
supporting hub, switch, router or another computer. This is a "Ping-Pong" test. This test cannot be
completed unless there are minimum two computers on the LAN for sending or receiving the test
packets.
For the <Run Diagnostics On Network> test
Master Machine: Master machine sends magic packet or
Wake up frame through the network.
Target Machine: Target machine is notified whenever a
qualified wakeup packet is received.
To Wake-Up The Target Machine With A Magic Packet
Step1: Target Machine:
Check BIOS <POWER MANGEMENT SETUP> ACPI, Wake-On-LAN function must be
enabled.
Step2: Target Machine:
Select <Target Machine> then the system will setup a wake-up event and wait for a magic packet
to do the system wake-up
Step3: Master Machine:
Select <Magic Packet> to send a magic packet and wake-up the target machine. The MAC
address of the target machine is required, such as: 00 e0 7d c0 00 02.
Step4: Target Machine:
ACPI Testing events will be displayed
Device State 1:
PASS
Device State 2:
PASS
Device State 3:
PASS
Step5: Target Machine:
Power down the target machine.
Step6: Master Machine:
Send a magic packet to wake-up the target machine.
Network
Ethernet Address
00E07DC00002
Target Machine
Ethernet Address
00E07DC00001
Master Machine