- 37 -
8.3 Handling
1. Do not touch the motor while in operation.
The surface temperature of the motor can increase to approx. 90oC to 100oC due to operating
conditions. This temperature increase may also be caused by energizing alone. As it may cause burns,
do not touch the motor when in operation.
2. If abnormal heating, smoking or fire, etc., occurs in the product, immediately shut off the power
supply.
3. Immediately stop operation if abnormal operation noise or vibration occurs.
In case abnormal operation noise or vibration occurs, the product may have been improperly mounted.
Unless operation is stopped for inspection, machinery can be seriously damaged.
4. Never touch the rotating part of the motor while in operation.
5.
When installing, adjusting, inspecting or performing maintenance on the product, controller and related
equipment, be sure to shut off the power supply to each of them. Then, lock it so that no one other than
the person working can turn the power on, or implement measures such as a safety plug.
6.
In the case of the actuator that has a servo motor (24VDC), the “motor phase detection step" is
done by inputting the servo on signal just after the controller power is turned on. The “motor
phase detection step” moves the table/rod for the distance of the one screw-lead as the
maximum. (The motor rotates in the reverse direction if the table hits an obstacle such as the
end stop damper.) Take the “motor phase detection step” into consideration for the installation
and operation of this actuator.
1.
Keep the controller and product combined as delivered for use.
The product is set in parameters for shipment. If it is combined with a different parameter, failure can result.
2.
Check the product for the following points before operation.
a) Damage to electric driving line and signal lines
b) Looseness of the connector to each power line and signal line
c) Looseness of the actuator/cylinder and controller/driver mounting
d) Abnormal operation
e) Emergency stop of the total system
3. When more than one person is performing work, decide on the procedures, signals, measures
and resolution for abnormal conditions before beginning the work. Also, designate a person to
supervise work other than those performing work.
4.
The product can operate at a different speed from the set speed depending on load and resistance.
When selecting a product, check the catalog for the instructions regarding selection and specifications.
5.
Do not apply a load, impact or resistance in addition to a transferred load during return to origin.
The product is made return to origin by pushing force, which causes the displacement of origin.
6. Do not remove the name plate.
7. Operation test should be done by low speed. Start operation by predefined speed after
confirming there is no trouble.
[Earth]
1.
Please give the earth to the actuator.
2.
The earth should be exclusive use. (Less than 100Ω)
3.
The earth cable length should be as short as possible.
! Warning
! Caution
! Warning