14
Talking Thermostat™
Model VT3000
Quick Set-Up & Installer’s Guide
Cautions!
◊
To prevent electrical shock and/or equipment damage, turn off power at the main service
panel by removing the fuse or switching circuit breaker to OFF position until removal of
existing and installation of the Talking Thermostat is complete.
◊
This thermostat must be installed in conformance with all local and national building and
electrical codes.
◊
Use only on single transformer systems.
Step 1: Mount Sub Base & Connect Wiring
◊
Mount sub base to wall using enclosed screws and anchors.
◊
Attach system wires to sub base terminals according to the system manufacturer’s
diagrams (Talking Thermostat suggested wiring diagrams on
pages 16 & 17).
Step 2: Set DIP Switches
◊
Determine the type of heating and
cooling system
Locate DIP switches on circuit
board immediately below the
battery bracket, left of the RJ45 jack
Set DIP switches for your type
system according to chart (chart is
shown right)
Note: for thermostat to operate
correctly the DIP switches must be
set to match the system
Note: Default Settings
!
◊
For Heat Pump / Dual Fuel systems, the chart below
might more clearly explain those DIP Switch settings:
By Type of Heat Pump System - DIP Switch Settings
n
o
it
i
s
o
P
/
#
h
c
ti
w
S
P
I
D
# 1
All Heat Pump Systems
ON
# 2
Dual Fuel Heat Pumps
OFF
Electric Aux Heat Pumps
ON
# 3
# 4
Heat Pump 1 Stage Compressor
OFF
OFF
Heat Pump 2 Stage Compressor
ON
ON
◊
◊
DIP Switch default settings: OFF, OFF, OFF, OFF (Conventional, Gas, 1 Stage
Heat, 1 Stage Cool)
Operation Settings, following default set OFF: UV Light Service Alert (UV)
IAQ Fan Run Time (FH) and Auto Change-Over (AC)
1