background image

 

Programming the Device for Model Mode or Disable Features 

 

Place the unit in Model Mode / Disable Features Program Mode:  

Hold the 

Water Only

  & 

Empty Only

 buttons down together for 3 seconds. The Holding 

Tank Full LED will give three flashes indicating you have entered program mode. While 
still holding down these two buttons, press the 

Normal Flush

 button. The Tank LED will 

give six flashes indicating you have entered Model Mode / Disable Features program 
mode, release both buttons.

 

 

Selecting Model Mode: 

Press the 

Normal Flush

 button, the Holding Tank Full LED will give four flashes 

indicating you have entered program Model Mode. 

You may now select which Model Mode you require: Press the 

Normal Flush

 button for 

Tecma

 

Silence

 

(Series)  

(model mode 2), the 

Empty Only

 button for

 Standard Mode 

(model mode 1) or the 

Water Only

 button for extended models, press the 

Normal Flush

 

for 

Tecma

 

Prestige (Series)  

(model mode 3)

 

or

 

the 

Water Only

 button for

 European  

Mode 

(model mode 4). The Tank LED will give three flashes indicating you have finished 

model program mode. 

 

Disable Features: 

You can disable or enable two features: 
1/ 

The Manual buttons

. If disabled the only button that will work is the Flush button. The 

Water Only

 and 

Empty Only

 buttons will be disabled

.  

 

2/

 Tank Full. If enabled and the tank is FULL the LED will be turn on and NO 

buttons will work. If disabled and the Tank is FULL the LED will be on and ALL 
buttons will still work. 

 

3/ Deactivation of the 

Water Only 

button after use. If this feature is enabled then after 

the 

Water Only

 button has been pushed and released it will be deactivated. The 

Empty

 

Only

 button will need to be pressed for at least 1 second to reactivate the 

Water Only

 

button. This feature can be disabled or enabled.  

 

Place the unit in Model / Disable Features Program Mode as above (top of page). 

 

Push the 

Empty Only

 button, the holding tank full LED will give three flashes indicating 

you have entered disable feature mode. 

 

You may now select which feature to disable.  

1/ Push the 

Normal Flush

 button disable or enable the Tank Full feature.  

2/ Push the 

Water Only

 button to disable or enable the Manual buttons. 

3/ Push the 

Empty Only

 button to disable or enable the 

Water Only

 button deactivation 

feature. 

 

The Tank LED will give three flashes indicating you have finished model program mode. 

 

Repeat the step to re enable these features.

 

NOTE:

 The factory default setting is on for both of these features.  

 

Summary of Contents for STS-220

Page 1: ...line clearance when the manual touch pads are used In built troubleshooting features and toilet pump protection are standard This Product has been Factory Preset to operate effectively without making...

Page 2: ...Warning 1 5 litres per flush is the recommended minimum flush setting for discharge lines of less than 6 feet Dilution is the secret to efficient waste transfer through pipes and must be considered wh...

Page 3: ...value The unit will flash three times indicating the time has been set and you have left program mode Setting T2 Discharge Pump Time After placing the unit in program mode as in Step 1 above press the...

Page 4: ...ber of times required for the Water Inlet Discharge Pump time one press 1 second two 2 sec s etc The Tank LED will flash once indicating a valid key press Note If the button is pressed 21 times it wil...

Page 5: ...ater Valve Inlet Pump time one press 1 second two 2 sec s etc The Tank LED will flash once indicating a valid key press Note If the button is pressed 21 times it will start back at 1 second Once this...

Page 6: ...econds Model Mode 4 European Mode 2 sec s 2 sec s Start T1 Water Inlet Off T2 Discharge Motor Off T3 Water Inlet Programmable from 1 20 sec s Programmable from 1 20 sec s Programmable from 0 20 sec s...

Page 7: ...1 The Manual buttons If disabled the only button that will work is the Flush button The Water Only and Empty Only buttons will be disabled 2 Tank Full If enabled and the tank is FULL the LED will be t...

Page 8: ...lush For Model LED will give four flashes Push Normal Flush Tecma Silence Series Push Water Only extended models Push Empty Only Standard Mode Push Empty Only For Disable Enable features LED will give...

Page 9: ...Empty Only While this button is held down the discharge pump will activate Maximum 20 seconds per press Holding Tank Full Optional If the vessel is fitted with a Holding Tank Full Sensor Switch it can...

Page 10: ...10 Connections FIG 1 Toilet Control Flush Tank Full Float Switch Battery Positive Battery Negative Discharge Pump EST Not used Water Inlet Pump Valve Water Inlet Pump Valve Discharge Pump GND...

Page 11: ...oth Clip in place Toilet Control Toilet Control 72mm 115mm 84mm 13mm Warning This device should be fuse protected and mounted in a dry area as close to the Toilet as is practical DO NOT cover the vent...

Page 12: ...ll technologies design and Intellectual property is owned by Penguin Electronics Ltd Po Box 272 Waikanae NZ Phone 0064 4 293 4201 Fax 0064 4 293 4201 Email info smartswitch co nz Web www smartswitch c...