4
Programming for Tecma Silence (Series) Model
Mode 2
Step 1
– Placing the unit in program mode:
After wiring and applying power
,
hold the
Water Only
&
Empty Only
buttons down
together for 3 seconds. The Holding Tank Full LED will give three quick flashes
indicating you have entered program mode. You may now release both buttons.
Once in program mode you can now program one of the following two times: T1 = Water
Inlet / Discharge Pump or T3 = Water Valve/Inlet Pump.
Step 1
will need to be repeated for each of these delay times.
Tecma mode differs as the water inlet and pump discharge times work together:
The pump discharge time will be half (1/2) of the T1 = Water Inlet time (see timing chart
page 6) therefore
ONLY
T1 & T3 need to be programmed.
Setting T1: Water Inlet / Discharge Pump Time:
After placing the unit in program mode, as in
Step 1
above
,
press the
Normal Flush
button the number of times required for the Water Inlet / Discharge Pump time (one
press =1 second, two = 2 sec’s, etc). The Tank LED will flash once indicating a valid key
press. Note: If the button is pressed 21 times it will start back at 1 second.
Once this is done press the
Empty Only
button to store this value. The unit will flash
three times indicating the time has been set and you have left program mode.
Setting T3: Water Valve/Inlet Pump Time:
After placing the unit in program mode, as in
Step 1
above, press the
Water Only
button
the number of times required for the Water Valve/Inlet Pump time (one press = 0 sec’s,
two = 1 second, three = 2 sec’s, etc). The Tank LED will flash once indicating a valid key
press. Note: If the button is pressed 21 times it will start back at 0 seconds.
Once this is done press the
Normal Flush
button to store this value. The unit will flash
three times indicating the time has been set and you have left program mode.
Programming for Tecma Prestige (Series)
Model
Mode 3
There is no programming required for this mode as the times are fixed (see timing chart
page 6).